Suppr超能文献

第一代高交联聚乙烯的磨损和骨溶解结果的历史和系统回顾。

History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene.

机构信息

Exponent, Inc, 3401 Market Street, Suite 300, Philadelphia, PA 19104, USA.

出版信息

Clin Orthop Relat Res. 2011 Aug;469(8):2262-77. doi: 10.1007/s11999-011-1872-4.

Abstract

BACKGROUND

Highly crosslinked polyethylene (HXLPE) was introduced to reduce wear and osteolysis in total joint arthroplasty. While many studies report wear and osteolysis associated with HXLPE, analytical techniques, clinical study design and followup, HXLPE formulation and implant design characteristics, and patient populations differ substantially among investigations, complicating a unified perspective.

QUESTIONS/PURPOSES: Literature on first-generation HXLPE was summarized. We systematically reviewed the radiographic wear data and incidence of osteolysis for HXLPE in hip and knee arthroplasty.

METHODS

PubMed identified 391 studies; 28 met inclusion criteria for a weighted-averages analysis of two-dimensional femoral head penetration rates. To determine the incidence of osteolysis, we estimated a pooled odds ratio using a random-effects model.

RESULTS

Weighted-averages analyses of femoral head penetration rates in HXLPE liners and conventional UHMWPE liners resulted, respectively, in a mean two-dimensional linear penetration rate of 0.042 mm/year based on 28 studies (n=1503 hips) and 0.137 mm/year based on 18 studies (n=695 hips). The pooled odds ratio for the risk of osteolysis in HXLPE versus conventional liners was 0.13 (95% confidence interval, 0.06-0.27) among studies with minimum 5-year followup. We identified two clinical studies of HXLPE in TKA, preventing systematic analysis of outcomes.

CONCLUSIONS

HXLPE liner studies consistently report lower femoral head penetration and an 87% lower risk of osteolysis. Reduction in femoral head penetration or osteolysis risk is not established for large-diameter (>32 mm) metallic femoral heads or ceramic femoral heads of any size. Few studies document the clinical performance of HXLPE in knees.

摘要

背景

高度交联聚乙烯(HXLPE)的引入是为了减少全关节置换术中的磨损和骨溶解。虽然许多研究报告了与 HXLPE 相关的磨损和骨溶解,但分析技术、临床研究设计和随访、HXLPE 配方和植入物设计特点以及患者人群在研究中存在很大差异,这使得难以形成统一的观点。

问题/目的:总结第一代 HXLPE 的文献。我们系统地回顾了髋关节和膝关节置换术中 HXLPE 的放射学磨损数据和骨溶解发生率。

方法

通过 PubMed 确定了 391 项研究;28 项符合纳入标准,可进行二维股骨头穿透率的加权平均值分析。为了确定骨溶解的发生率,我们使用随机效应模型估计了合并的优势比。

结果

基于 28 项研究(n=1503 髋),HXLPE 衬里和传统超高分子量聚乙烯衬里的股骨头穿透率加权平均值分析分别得出二维线性穿透率的平均值为 0.042mm/年,基于 18 项研究(n=695 髋)的结果为 0.137mm/年。在随访时间至少为 5 年的研究中,HXLPE 与传统衬里相比,骨溶解风险的合并优势比为 0.13(95%置信区间,0.06-0.27)。我们发现了两项关于 TKA 中 HXLPE 的临床研究,这使得无法对结果进行系统分析。

结论

HXLPE 衬里研究一致报告股骨头穿透率较低,骨溶解风险降低 87%。对于大直径(>32mm)金属股骨头或任何尺寸的陶瓷股骨头,股骨头穿透率或骨溶解风险的降低尚未得到证实。很少有研究记录 HXLPE 在膝关节中的临床性能。

相似文献

1
History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene.
Clin Orthop Relat Res. 2011 Aug;469(8):2262-77. doi: 10.1007/s11999-011-1872-4.
3
Do oxidized zirconium femoral heads reduce polyethylene wear in cemented THAs? A blinded randomized clinical trial.
Clin Orthop Relat Res. 2015 Dec;473(12):3822-8. doi: 10.1007/s11999-015-4414-7.
4
The addition of vitamin E could reduce femoral head penetration of the polyethylene liners.
J Orthop Surg Res. 2025 Jan 20;20(1):72. doi: 10.1186/s13018-024-05402-7.
5
Low wear rates seen in THAs with highly crosslinked polyethylene at 9 to 14 years in patients younger than age 50 years.
Clin Orthop Relat Res. 2015 Dec;473(12):3829-35. doi: 10.1007/s11999-015-4422-7.
6
Is there a role for femoral offset restoration during total hip arthroplasty? A systematic review.
Orthop Traumatol Surg Res. 2017 May;103(3):349-355. doi: 10.1016/j.otsr.2016.12.013. Epub 2017 Jan 31.
8
9
Femoral Head Penetration Rates of Second-Generation Sequentially Annealed Highly Cross-Linked Polyethylene at Minimum Five Years.
J Arthroplasty. 2019 Apr;34(4):781-788. doi: 10.1016/j.arth.2018.12.004. Epub 2018 Dec 7.

引用本文的文献

2
Is it safe to use ceramic on polyethylene bearings in revision hip arthroplasty for ceramic fracture?
Bone Jt Open. 2025 Jun 13;6(6):700-706. doi: 10.1302/2633-1462.66.BJO-2025-0030.R1.
4
[Long-term computed tomographic osteolytic analysis of highly cross-linked polyethylene prosthesis after total hip arthroplasty].
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2024 Sep 15;38(9):1079-1085. doi: 10.7507/1002-1892.202403040.
7
Towards the First Generation of Biomimetic Fixation for Resurfacing Arthroplasty Endoprostheses.
Biomimetics (Basel). 2024 Feb 8;9(2):99. doi: 10.3390/biomimetics9020099.
9
Antibiotic-Loaded Ultrahigh Molecular Weight Polyethylenes.
Macromol Biosci. 2024 Apr;24(4):e2300389. doi: 10.1002/mabi.202300389. Epub 2024 Jan 7.
10
In Vitro Wear of a Novel Vitamin E Crosslinked Polyethylene Lumbar Total Joint Replacement.
Bioengineering (Basel). 2023 Oct 15;10(10):1198. doi: 10.3390/bioengineering10101198.

本文引用的文献

1
Do first-generation highly crosslinked polyethylenes oxidize in vivo?
Clin Orthop Relat Res. 2011 Aug;469(8):2278-85. doi: 10.1007/s11999-010-1728-3.
2
The incidence of acetabular osteolysis in young patients with conventional versus highly crosslinked polyethylene.
Clin Orthop Relat Res. 2011 Feb;469(2):372-81. doi: 10.1007/s11999-010-1518-y.
3
Do "premium" joint implants add value?: analysis of high cost joint implants in a community registry.
Clin Orthop Relat Res. 2011 Jan;469(1):48-54. doi: 10.1007/s11999-010-1436-z.
4
Highly crosslinked polyethylene reduces wear in total hip arthroplasty at 5 years.
Clin Orthop Relat Res. 2010 Dec;468(12):3228-33. doi: 10.1007/s11999-010-1379-4.
6
Clinical, surface damage and oxidative performance of poly II tibial inserts after long-term implantation.
J Long Term Eff Med Implants. 2008;18(2):151-65. doi: 10.1615/jlongtermeffmedimplants.v18.i2.40.
9
Wear and range of motion of different femoral head sizes.
J Arthroplasty. 2010 Sep;25(6):839-43. doi: 10.1016/j.arth.2009.07.007. Epub 2009 Sep 23.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验