Suppr超能文献

一种新型的、基于显微镜的、非侵入式的激光多普勒血流计,用于评估脉络膜血流。

A novel, microscope based, non-invasive laser Doppler flowmeter for choroidal blood flow assessment.

机构信息

Department of Ophthalmology and Optometry, Paracelsus Medical University, Müllner Haupstrasse 48, Salzburg 5020, Austria.

出版信息

Exp Eye Res. 2011 Jun;92(6):545-51. doi: 10.1016/j.exer.2011.03.014. Epub 2011 Apr 1.

Abstract

Impaired ocular blood flow is involved in the pathogenesis of numerous ocular diseases like glaucoma or AMD. The purpose of the present study was to introduce and validate a novel, microscope based, non-invasive Laser Doppler Flowmeter (NI-LDF) for measurement of blood flow in the choroid. The custom made NI-LDF was compared with a commercial fiber optic based laser Doppler flowmeter (Perimed PF4000). Linearity and stability of the NI-LDF were assessed in a silastic tubing model (i.d. 0.3 mm) at different flow rates (range 0.4-3 ml/h). In a rabbit model continuous choroidal blood flow measurements were performed with both instruments simultaneously. During blood flow measurements ocular perfusion pressure was changed by manipulations of intraocular pressure via intravitreal saline infusions. The NI-LDF measurement correlated linearly to intraluminal flow rates in the perfused tubing model (r = 0.99, p < 0.05) and remained stable during a 1 h measurement at a constant flow rate. Rabbit choroidal blood flow measured by the PF4000 and the NI-LDF linearly correlated with each other over the entire measurement range (r = 0.99, y = x∗1.01-12.35 P.U., p < 0.001). In conclusion, the NI-LDF provides valid, semi quantitative measurements of capillary blood flow in comparison to an established LDF instrument and is suitable for measurements at the posterior pole of the eye.

摘要

眼部血流受损与许多眼部疾病的发病机制有关,如青光眼或 AMD。本研究旨在介绍和验证一种新的、基于显微镜的、非侵入性激光多普勒血流仪(NI-LDF),用于测量脉络膜的血流。定制的 NI-LDF 与商用光纤激光多普勒血流仪(Perimed PF4000)进行了比较。在不同流速(范围 0.4-3ml/h)下,在硅橡胶管模型(内径 0.3mm)中评估了 NI-LDF 的线性度和稳定性。在兔模型中,同时使用两种仪器进行连续脉络膜血流测量。在血流测量过程中,通过眼内盐水输注来改变眼内压,从而改变眼内灌注压。NI-LDF 测量值与灌注管模型内的腔内流速呈线性相关(r=0.99,p<0.05),在恒定流速下测量 1 小时内保持稳定。PF4000 和 NI-LDF 测量的兔脉络膜血流在整个测量范围内呈线性相关(r=0.99,y=x*1.01-12.35PU,p<0.001)。总之,NI-LDF 与已建立的 LDF 仪器相比,可提供毛细血管血流的有效、半定量测量,适用于眼部后极的测量。

相似文献

1
A novel, microscope based, non-invasive laser Doppler flowmeter for choroidal blood flow assessment.
Exp Eye Res. 2011 Jun;92(6):545-51. doi: 10.1016/j.exer.2011.03.014. Epub 2011 Apr 1.
2
Compact Laser Doppler Flowmeter (LDF) Fundus Camera for the Assessment of Retinal Blood Perfusion in Small Animals.
PLoS One. 2015 Jul 30;10(7):e0134378. doi: 10.1371/journal.pone.0134378. eCollection 2015.
3
Regional distribution of optic nerve head blood flow.
Graefes Arch Clin Exp Ophthalmol. 1999 Jun;237(6):484-8. doi: 10.1007/s004170050266.
4
Ocular blood flow assessment using continuous laser Doppler flowmetry.
Acta Ophthalmol. 2010 Sep;88(6):622-9. doi: 10.1111/j.1755-3768.2009.01621.x.
5
Choroidal laser Doppler flowmetry in healthy subjects.
Arch Ophthalmol. 2000 Feb;118(2):211-5. doi: 10.1001/archopht.118.2.211.
6
Effects of dorzolamide on choroidal blood flow, ciliary blood flow, and aqueous production in rabbits.
Invest Ophthalmol Vis Sci. 2009 May;50(5):2301-7. doi: 10.1167/iovs.08-2468. Epub 2009 Jan 31.
7
Improvement of the detection of human pulpal blood flow using a laser Doppler flowmeter modified for low flow velocity.
Arch Oral Biol. 2014 Feb;59(2):199-206. doi: 10.1016/j.archoralbio.2013.11.009. Epub 2013 Nov 26.
9
Choroidal hemodynamic in myopic patients with and without primary open-angle glaucoma.
Acta Ophthalmol. 2013 Jun;91(4):371-5. doi: 10.1111/j.1755-3768.2012.02386.x. Epub 2012 Mar 28.

引用本文的文献

1
Compact Laser Doppler Flowmeter (LDF) Fundus Camera for the Assessment of Retinal Blood Perfusion in Small Animals.
PLoS One. 2015 Jul 30;10(7):e0134378. doi: 10.1371/journal.pone.0134378. eCollection 2015.
2
Is There Any Role for the Choroid in Glaucoma?
J Glaucoma. 2016 May;25(5):452-8. doi: 10.1097/IJG.0000000000000166.

本文引用的文献

1
Higher order moment processing of laser Doppler perfusion signals.
J Biomed Opt. 1997 Oct;2(4):358-63. doi: 10.1117/12.281499.
2
Model for laser Doppler measurements of blood flow in tissue.
Appl Opt. 1981 Jun 15;20(12):2097-107. doi: 10.1364/AO.20.002097.
3
Effects of dorzolamide on choroidal blood flow, ciliary blood flow, and aqueous production in rabbits.
Invest Ophthalmol Vis Sci. 2009 May;50(5):2301-7. doi: 10.1167/iovs.08-2468. Epub 2009 Jan 31.
4
Observation of erythrocyte dynamics in the retinal capillaries and choriocapillaris using ICG-loaded erythrocyte ghost cells.
Invest Ophthalmol Vis Sci. 2008 Dec;49(12):5510-6. doi: 10.1167/iovs.07-1504. Epub 2008 Aug 15.
5
Relationship between ciliary blood flow and aqueous production in rabbits.
Invest Ophthalmol Vis Sci. 2003 Sep;44(9):3967-71. doi: 10.1167/iovs.03-0088.
9
Blood flow in the human iris measured by laser Doppler flowmetry.
Microvasc Res. 1999 Mar;57(2):153-61. doi: 10.1006/mvre.1998.2136.
10
Quantification of erythrocyte flow in the choroid of the albino rat.
Am J Physiol. 1997 Mar;272(3 Pt 2):H1444-53. doi: 10.1152/ajpheart.1997.272.3.H1444.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验