Test-retest reliability of arterial spin labeling with common labeling strategies.

机构信息

Department of Neurology, University of Pennsylvania, Philadelphia, PA, USA.

出版信息

J Magn Reson Imaging. 2011 Apr;33(4):940-9. doi: 10.1002/jmri.22345.

Abstract

PURPOSE

To compare the test-retest reproducibility of three variants of arterial spin labeling (ASL): pseudo-continuous (pCASL), pulsed (PASL) and continuous (CASL).

MATERIALS AND METHODS

Twelve healthy subjects were scanned on a 3.0T scanner with PASL, CASL, and pCASL. Scans were repeated within-session, after 1 hour, and after 1 week to assess reproducibility at different scan intervals.

RESULTS

Comparison of within-subject coefficients of variation (wsCV) demonstrated high within-session reproducibility (ie, low wsCV) for CASL-based methods (gray matter [GM] wsCV for pCASL: 3.5% ± 0.02%, CASL: 4.1% ± 0.07%) compared to PASL (wsCV: 7.5% ± 0.06%), due to the higher signal-to-noise ratio (SNR) associated with continuous labeling, evident in the 20% gain in temporal SNR and 58% gain in raw SNR for pCASL relative to PASL. At the 1-week scan interval, comparable reproducibility between PASL (GM wsCV 9.2% ± 0.12%) and pCASL (GM wsCV 8.5% ± 0.14%) was observed, indicating the dominance of physiological fluctuations.

CONCLUSION

Although all three approaches are capable of measuring cerebral blood flow within a few minutes of scanning, the high precision and SNR of pCASL, with its insensitivity to vessel geometry, make it an appealing method for future ASL application studies.

摘要

目的

比较三种动脉自旋标记(ASL)变体(伪连续式 ASL [pCASL]、脉冲式 ASL [PASL]和连续式 ASL [CASL])的测试-再测试可重复性。

材料与方法

12 名健康受试者在 3.0T 扫描仪上接受 PASL、CASL 和 pCASL 扫描。在同一时段内、1 小时后和 1 周后重复扫描,以评估不同扫描间隔的可重复性。

结果

比较受试者内变异系数(wsCV),基于 CASL 的方法(灰质 [GM] pCASL 的 wsCV:3.5%±0.02%,CASL:4.1%±0.07%)显示出较高的同时间段内可重复性(即低 wsCV),与 PASL(wsCV:7.5%±0.06%)相比,这归因于连续标记相关的更高信噪比(SNR),这在 pCASL 相对于 PASL 的 20%的时间 SNR 增益和 58%的原始 SNR 增益中显而易见。在 1 周的扫描间隔,观察到 PASL(GM wsCV 9.2%±0.12%)和 pCASL(GM wsCV 8.5%±0.14%)之间具有可比性的可重复性,表明生理波动的主导作用。

结论

尽管三种方法都能够在扫描几分钟内测量脑血流,但 pCASL 的高精度和 SNR,以及其对血管几何形状的不敏感性,使其成为未来 ASL 应用研究的一种有吸引力的方法。

相似文献

1
Test-retest reliability of arterial spin labeling with common labeling strategies.
J Magn Reson Imaging. 2011 Apr;33(4):940-9. doi: 10.1002/jmri.22345.
2
Test-retest reliability and reproducibility of long-label pseudo-continuous arterial spin labeling.
Magn Reson Imaging. 2020 Nov;73:111-117. doi: 10.1016/j.mri.2020.07.010. Epub 2020 Jul 25.
6
Pseudocontinuous arterial spin labeling perfusion magnetic resonance imaging--a normative study of reproducibility in the human brain.
Neuroimage. 2011 Jun 1;56(3):1244-50. doi: 10.1016/j.neuroimage.2011.02.080. Epub 2011 Mar 6.
7
Reliability and Reproducibility of Hadamard Encoded Pseudo-Continuous Arterial Spin Labeling in Healthy Elderly.
Front Neurosci. 2021 Aug 19;15:711898. doi: 10.3389/fnins.2021.711898. eCollection 2021.
10
Comparison of pulsed and pseudocontinuous arterial spin-labeling for measuring CO2 -induced cerebrovascular reactivity.
J Magn Reson Imaging. 2012 Aug;36(2):312-21. doi: 10.1002/jmri.23658. Epub 2012 Apr 27.

引用本文的文献

2
Whole-cerebrum three-dimensional pseudo-continuous arterial spin labeling at 5T: reproducibility and preliminary application in moyamoya.
Quant Imaging Med Surg. 2025 May 1;15(5):3824-3838. doi: 10.21037/qims-24-2274. Epub 2025 Apr 28.
4
Compensatory increase in oxygen extraction fraction is associated with age-related cerebrovascular disease.
Neuroimage Clin. 2025;45:103746. doi: 10.1016/j.nicl.2025.103746. Epub 2025 Jan 28.
5
Revealing the Spatial Pattern of Brain Hemodynamic Sensitivity to Healthy Aging through Sparse Dynamic Causal Model.
J Neurosci. 2025 Jan 1;45(1):e1940232024. doi: 10.1523/JNEUROSCI.1940-23.2024.

本文引用的文献

2
Theoretical and experimental evaluation of continuous arterial spin labeling techniques.
Magn Reson Med. 2010 Feb;63(2):438-46. doi: 10.1002/mrm.22243.
4
The QUASAR reproducibility study, Part II: Results from a multi-center Arterial Spin Labeling test-retest study.
Neuroimage. 2010 Jan 1;49(1):104-13. doi: 10.1016/j.neuroimage.2009.07.068. Epub 2009 Aug 4.
5
Acquisition time and reproducibility of continuous arterial spin-labeling perfusion imaging at 3T.
AJNR Am J Neuroradiol. 2009 May;30(5):968-71. doi: 10.3174/ajnr.A1454. Epub 2009 Feb 4.
7
Intraclass correlations: uses in assessing rater reliability.
Psychol Bull. 1979 Mar;86(2):420-8. doi: 10.1037//0033-2909.86.2.420.
9
Reproducibility of continuous arterial spin labeling perfusion MRI after 7 weeks.
MAGMA. 2007 Apr;20(2):103-15. doi: 10.1007/s10334-007-0073-3. Epub 2007 Apr 11.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验