Smith T O, Drew B T, Toms A P, Chojnowski A J
School of Allied Health Professions,University of East Anglia, Norwich, UK.
J Hand Surg Eur Vol. 2012 Nov;37(9):879-87. doi: 10.1177/1753193411402762. Epub 2011 Apr 5.
The purpose of this study was to evaluate the diagnostic test accuracy of X-ray arthrography in the detection of TFCC tear. Both published and unpublished databases were searched from their inception to August 2010. All studies comparing the diagnostic accuracy of X-ray arthrography (index test) to arthroscopy (reference standard) for patients with suspected TFCC tears were included in this review. Twelve studies assessing 430 patients (430 wrists) satisfied the eligibility criteria and were included. X-ray arthrography presented with a pooled sensitivity of 76.2% and specificity of 92.5% for the detection of complete TFCC tear. The triple-compartment injection X-ray arthrography was superior to the single-compartment injection technique. To conclude, the diagnostic test accuracy of X-ray arthrography is limited. Neither the single- nor the triple-compartment injection arthrography method is acceptable, given their reported low sensitivities. Further evaluation of the diagnostic test accuracy of Magnetic Resonance Arthrography and Magnetic Resonance Imaging is therefore warranted.
本研究的目的是评估X线关节造影术检测三角纤维软骨复合体(TFCC)撕裂的诊断试验准确性。从数据库建立之初到2010年8月,对已发表和未发表的数据库进行了检索。本综述纳入了所有比较X线关节造影术(索引试验)与关节镜检查(参考标准)对疑似TFCC撕裂患者的诊断准确性的研究。12项评估430例患者(430个腕关节)的研究符合纳入标准并被纳入。X线关节造影术检测完全性TFCC撕裂的合并敏感度为76.2%,特异度为92.5%。三室注射X线关节造影术优于单室注射技术。总之,X线关节造影术的诊断试验准确性有限。鉴于单室和三室注射关节造影术的敏感度均较低,这两种方法均不可接受。因此,有必要进一步评估磁共振关节造影术和磁共振成像的诊断试验准确性。