Suppr超能文献

高效液相色谱-二极管阵列检测法测定工作场所空气中 2,2'-二氯-4,4'-亚甲基二苯胺

A new method for the determination of 2,2'-dichloro-4,4'-methylenedianiline in workplace air samples by HPLC-DAD.

机构信息

Central Institute for Labour Protection-National Research Institute, Warszawa, Poland.

出版信息

Toxicol Mech Methods. 2011 Sep;21(7):554-60. doi: 10.3109/15376516.2011.571726. Epub 2011 Apr 8.

Abstract

A new procedure has been developed for the assay of 2,2'-dichloro-4,4'-methylenedianiline (MOCA) using high-performance liquid chromatography with diode array detector. MOCA was sampled from workplace air and derivative before determination using 3,5-dinitrobenzoyl chloride. The determination was carried out in the reverse-phase system (mobile phase: acetonitrile: water) using an Ultra C(18) column. The measurement range was 2-40 µg/m(3) for a 100 dm(3) air sample. Limit of detection: 7.9 ng/m(3) and limit of quantification: 23.8 ng/m(3).

摘要

已开发出一种新方法,用于使用带有二极管阵列检测器的高效液相色谱法测定 2,2'-二氯-4,4'-亚甲基二苯胺(MOCA)。使用 3,5-二硝基苯甲酰氯对工作场所空气中的 MOCA 进行采样并衍生后进行测定。测定在反相系统(流动相:乙腈:水)中使用 Ultra C(18)柱进行。测量范围为 100 dm(3)空气样品中 2-40 µg/m(3)。检出限:7.9 ng/m(3)和定量限:23.8 ng/m(3)。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验