儿童人体测量学指标的测量者内和测量者间可靠性。

Intra- and inter-observer reliability in anthropometric measurements in children.

机构信息

Department of Paediatrics, Medical Faculty, University of Pecs, Hungary.

出版信息

Int J Obes (Lond). 2011 Apr;35 Suppl 1:S45-51. doi: 10.1038/ijo.2011.34.

Abstract

INTRODUCTION

Studies such as IDEFICS (Identification and prevention of dietary- and lifestyle-induced health effects in children and infants) seek to compare data across several different countries. Therefore, it is important to confirm that body composition indices, which are subject to intra- and inter-individual variation, are measured using a standardised protocol that maximises their reliability and reduces error in analyses.

OBJECTIVE

To describe the standardisation and reliability of anthropometric measurements. Both intra- and inter-observer variability of skinfold thickness (triceps, subscapular, biceps, suprailiac) and circumference (neck, arm, waist, hip) measurements were investigated in five different countries.

METHODS

Central training for fieldwork personnel was carried out, followed by local training in each centre involving the whole survey staff. All technical devices and procedures were standardised. As part of the standardisation process, at least 20 children participated in the intra- and inter-observer reliability test in each centre. A total of 125 children 2-5 years of age and 164 children 6-9 years of age took part in this study, with a mean age of 5.4 (± 1.2) years.

RESULTS

The intra-observer technical error of measurement (TEM) was between 0.12 and 0.47 mm for skinfold thickness and between 0.09 and 1.24 cm for circumference measurements. Intra-observer reliability was 97.7% for skinfold thickness (triceps, subscapular, biceps, suprailiac) and 94.7% for circumferences (neck, arm, waist, hip). Inter-observer TEMs for skinfold thicknesses were between 0.13 and 0.97 mm and for circumferences between 0.18 and 1.01 cm. Inter-observer agreement as assessed by the coefficient of reliability for repeated measurements of skinfold thickness and circumferences was above 88% in all countries.

CONCLUSION

In epidemiological surveys it is essential to standardise the methodology and train the participating staff in order to decrease measurement error. In the framework of the IDEFICS study, acceptable intra- and inter-observer agreement was achieved for all the measurements.

摘要

简介

IDEFICS(儿童和婴儿饮食和生活方式引起的健康影响的识别和预防)等研究旨在比较多个不同国家的数据。因此,重要的是要确认,身体成分指数,这些都是受到个体内和个体间的变化,使用一个标准化的协议,最大限度地提高其可靠性和减少分析中的误差进行测量。

目的

描述人体测量的标准化和可靠性。在五个不同的国家,研究了皮褶厚度(三头肌、肩胛下、肱二头肌、骼前上棘)和周长(颈部、臂部、腰部、臀部)测量的观察者内和观察者间的变异性。

方法

对现场工作人员进行了集中培训,然后在每个中心进行了包括整个调查人员在内的当地培训。所有的技术设备和程序都进行了标准化。作为标准化过程的一部分,每个中心至少有 20 名儿童参加了观察者内和观察者间的可靠性测试。共有 125 名 2-5 岁的儿童和 164 名 6-9 岁的儿童参加了这项研究,平均年龄为 5.4(±1.2)岁。

结果

皮褶厚度的观察者内技术测量误差(TEM)为 0.12 至 0.47 毫米,周长测量的 TEM 为 0.09 至 1.24 厘米。皮褶厚度(三头肌、肩胛下、肱二头肌、骼前上棘)的观察者内可靠性为 97.7%,周长(颈部、臂部、腰部、臀部)的可靠性为 94.7%。皮褶厚度的观察者间 TEM 为 0.13 至 0.97 毫米,周长的 TEM 为 0.18 至 1.01 厘米。在所有国家,皮褶厚度和周长的重复测量的可靠性系数评估的观察者间一致性均高于 88%。

结论

在流行病学调查中,必须对方法进行标准化,并对参与的工作人员进行培训,以减少测量误差。在 IDEFICS 研究的框架内,所有测量都达到了可接受的观察者内和观察者间一致性。