Suppr超能文献

跟骨的宽带超声衰减:与其他骨骼部位骨矿物质的关系。

Broadband ultrasound attenuation in the os calcis: relationship to bone mineral at other skeletal sites.

作者信息

McCloskey E V, Murray S A, Miller C, Charlesworth D, Tindale W, O'Doherty D P, Bickerstaff D R, Hamdy N A, Kanis J A

机构信息

Department of Human Metabolism and Clinical Biochemistry, University of Sheffield Medical School, U.K.

出版信息

Clin Sci (Lond). 1990 Feb;78(2):227-33. doi: 10.1042/cs0780227.

Abstract
  1. We have examined the relationship between broadband ultrasound attenuation in the os calcis and measurements of bone mineral in the distal forearm and lumbar spine of normal and postmenopausal osteoporotic women. 2. Values of broadband ultrasound attenuation in postmenopausal women with vertebral osteoporotic fractures were significantly lower (35%) than in normal pre- and peri-menopausal women (55.4 +/- 3.8 and 79.6 +/- 0.8 dB/MHz, respectively). 3. Broadband ultrasound attenuation correlated significantly with bone mineral content measured in the distal forearm by single-photon absorptiometry (r = 0.77, P less than 0.0001) and with bone mineral content (r = 0.66, P less than 0.0001) and bone mineral density (r = 0.72, P less than 0.0001) measured in the lumbar spine by dual-photon absorptiometry. 4. Although significant, these correlations are not sufficiently close to be predictive. However, the accuracy of broadband ultrasound attenuation in discriminating between normal subjects and patients with vertebral fracture compared very favourably with direct measurements in the spine by dual-photon absorptiometry. 5. Broadband ultrasound attenuation, but not the other measurements, correlated significantly with age in the osteoporotic patients (r = 0.50, P less than 0.05). 6. These findings may reflect the partial dependence of broadband ultrasound attenuation on the intrinsic trabecular architecture of cancellous bone, the disruption of which contributes to an increase in fracture risk.
摘要
  1. 我们研究了正常及绝经后骨质疏松女性跟骨宽带超声衰减与前臂远端和腰椎骨矿物质测量值之间的关系。2. 有椎体骨质疏松性骨折的绝经后女性的宽带超声衰减值显著低于正常绝经前及围绝经期女性(分别为55.4±3.8和79.6±0.8dB/MHz,低35%)。3. 宽带超声衰减与通过单光子吸收法测量的前臂远端骨矿物质含量显著相关(r = 0.77,P<0.0001),也与通过双光子吸收法测量的腰椎骨矿物质含量(r = 0.66,P<0.0001)及骨矿物质密度(r = 0.72,P<0.0001)显著相关。4. 尽管相关性显著,但这些相关性不够紧密,无法用于预测。然而,与通过双光子吸收法直接测量脊柱相比,宽带超声衰减区分正常受试者和椎体骨折患者的准确性非常高。5. 在骨质疏松患者中,宽带超声衰减与年龄显著相关(r = 0.50,P<0.05),而其他测量值则不然。6. 这些发现可能反映了宽带超声衰减对松质骨内在小梁结构的部分依赖性,小梁结构的破坏会导致骨折风险增加。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验