Suppr超能文献

[使用ISIS(体内图像选择光谱法)和表面线圈的局部31P核磁共振光谱法:方法学及其在肝脏、移植肾和纵隔研究中的初步应用]

[Localized 31P-NMR-spectroscopy using ISIS (image-selected in vivo spectroscopy) and surface coils: methodology and initial applications to studies of the liver, the transplanted kidney and the mediastinum].

作者信息

Heindel W, Bunke J, Schreier G, Steinbrich W, Glathe S, Huttmann P

机构信息

Institut für Radiologische Diagnostik der Universität zu Köln.

出版信息

Rofo. 1990 Mar;152(3):277-82. doi: 10.1055/s-2008-1046868.

Abstract

A new method for image-guided localized phosphorus NMR spectroscopy of superficial tissues has been investigated using a 1.5 Tesla whole-body-MR-System. We used a surface coil combined with adiabatic excitation pulses and a modified ISIS sequence. This approach is related to imaging sequences and thus permits a flexible and accurate determination of the volume of interest from "conventional" proton images. The scope and advantages of the method are demonstrated by phantom studies. Clinical applications to the liver, renal transplants, and the mediastinum are described.

摘要

使用1.5特斯拉全身磁共振系统研究了一种用于浅表组织图像引导局部磷核磁共振波谱的新方法。我们使用了一个表面线圈,结合绝热激发脉冲和改进的ISIS序列。这种方法与成像序列相关,因此可以根据“传统”质子图像灵活、准确地确定感兴趣的体积。通过模型研究证明了该方法的范围和优势。描述了在肝脏、肾移植和纵隔的临床应用。