BACKGROUND

Accurately measuring physical activity (PA) with activity monitors requires sufficient monitor wear time which can be difficult to assess. Monitor sensitivity to movement and population characteristics (eg, children vs. adults) may dictate the duration of monitor inactivity indicative of nonwear. A standardized method for determining appropriate decision rules to identify wear time is needed.

METHODS

Several decision rules based on minimum durations of monitor inactivity (ie, 60, 90, 120, 150 minutes) to identify nonwear were applied to Stepwatch Activity Monitor data from 1064 adult bariatric surgical candidates. The frequency, pattern, and duration of resulting nonwear and wear periods were examined. Generalized Estimating Equations tested the effect of these decision rules on PA measures.

RESULTS

A 60-minute duration resulted in unreasonably large percentages of subjects with unlikely wear patterns [eg, ≥3 nonwear periods in a day (29.9%); ≥2 wear periods of less than an hour in a day (28.7%)]; 120 minutes appeared most reasonable. Wear time decision rules impacted PA measures.

CONCLUSIONS

The methods described in this paper can be used to determine appropriate instrument and population specific wear time decision rules. Recognizing monitor wear time is estimated, PA measures least affected by wear time are preferable.

摘要

背景

使用活动监测器准确测量身体活动 (PA) 需要足够的监测佩戴时间,而这可能难以评估。监测器对运动的敏感性和人口特征(例如,儿童与成人)可能决定了指示非佩戴的监测器静止时间的持续时间。需要一种标准化方法来确定适当的决策规则以确定佩戴时间。

方法

根据监测器静止时间(即 60、90、120、150 分钟)的最小持续时间,应用了几种决策规则来识别非佩戴,这些决策规则来自 1064 名成人减肥手术候选者的 Stepwatch 活动监测器数据。检查了由此产生的非佩戴和佩戴期的频率、模式和持续时间。广义估计方程测试了这些决策规则对 PA 测量的影响。

结果

60 分钟的持续时间导致具有不太可能佩戴模式的受试者百分比过高[例如,每天≥3 个非佩戴期(29.9%);每天≤1 小时的佩戴期≥2 个(28.7%)];120 分钟似乎最合理。佩戴时间决策规则影响 PA 测量。

结论

本文描述的方法可用于确定适当的仪器和特定人群的佩戴时间决策规则。认识到监测佩戴时间是估计的,受佩戴时间影响最小的 PA 测量值更可取。

相似文献

引用本文的文献

本文引用的文献

4
Physical activity in the United States measured by accelerometer.在美国,通过加速度计测量身体活动。
Med Sci Sports Exerc. 2008 Jan;40(1):181-8. doi: 10.1249/mss.0b013e31815a51b3.
8
Exercise effect on weight and body fat in men and women.运动对男性和女性体重及体脂的影响。
Obesity (Silver Spring). 2007 Jun;15(6):1496-512. doi: 10.1038/oby.2007.178.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验