Suppr超能文献

可植入式胶原晶状体植入术后客观前房深度变化及其对视力结果的影响:1年随访

Changes in objective vault and effect on vision outcomes after implantable Collamer lens implantation: 1-year follow-up.

作者信息

Du Gai-Ping, Huang Yi-Fei, Wang Li-Qiang, Wang Da-Jiang, Guo Hui-Ling, Yu Ji-Feng, Gong Yu-Bo, Song Jing, Huang Hou-Bing

机构信息

Department of Ophthalmology, The Chinese PLA General Hospital, Beijing, China.

出版信息

Eur J Ophthalmol. 2012 Mar-Apr;22(2):153-60. doi: 10.5301/EJO.2011.8359.

Abstract

PURPOSE

To investigate the changes in vault and the effect on visual outcomes 1 year after implantable Collamer lens (ICL) implantation.

METHODS

In this retrospective study, 127 eyes of 66 patients undergoing ICL implantation were examined both before and up to 1 year after the surgery. The examination contents included white-to-white (WTW) diameter, central vault of the ICL (distance between posterior surface of ICL and anterior surface of crystalline lens), refractive error, and wavefront high-order aberration (HOA). All statistical analyses were performed using SPSS 13.0 software.

RESULTS

A significant decrease in vault was noted up to 1 month, after which the value stabilized (p=0.001). The moderate vault decreased significantly after the first 3 months postsurgery (paired-samples t test, p<0.05). Low vault showed a tendency to increase and high vault showed a tendency to decrease, but not significantly, over time. There was no statistically significant correlation between the amount of vault and the refractive error (Pearson correlation coefficient R=0.111, p=0.473) and there was a statistically significant correlation between the vault and HOAs (R=0.304, p=0.024).

CONCLUSIONS

Implantable Collamer lens vault over the crystalline lens had the tendency toward a slight decrease with time and did not significantly affect the vision outcome 1 year after surgery.

摘要

目的

研究可植入式Collamer晶状体(ICL)植入术后1年眼房深度的变化及其对视觉效果的影响。

方法

在这项回顾性研究中,对66例接受ICL植入术患者的127只眼在手术前及术后长达1年的时间内进行了检查。检查内容包括白对白(WTW)直径、ICL的中央房深度(ICL后表面与晶状体前表面之间的距离)、屈光不正和波前高阶像差(HOA)。所有统计分析均使用SPSS 13.0软件进行。

结果

观察到房深度在术后1个月内显著下降,此后该值稳定(p = 0.001)。中等房深度在术后3个月后显著下降(配对样本t检验,p < 0.05)。随着时间的推移,低房深度呈增加趋势,高房深度呈下降趋势,但差异均无统计学意义。房深度量与屈光不正之间无统计学显著相关性(Pearson相关系数R = 0.111,p = 0.473),而房深度与高阶像差之间存在统计学显著相关性(R = 0.304,p = 0.024)。

结论

晶状体上方的可植入式Collamer晶状体房深度随时间有轻微下降趋势,且术后1年对视觉效果无显著影响。