To investigate the changes in vault and the effect on visual outcomes 1 year after implantable Collamer lens (ICL) implantation.
In this retrospective study, 127 eyes of 66 patients undergoing ICL implantation were examined both before and up to 1 year after the surgery. The examination contents included white-to-white (WTW) diameter, central vault of the ICL (distance between posterior surface of ICL and anterior surface of crystalline lens), refractive error, and wavefront high-order aberration (HOA). All statistical analyses were performed using SPSS 13.0 software.
A significant decrease in vault was noted up to 1 month, after which the value stabilized (p=0.001). The moderate vault decreased significantly after the first 3 months postsurgery (paired-samples t test, p<0.05). Low vault showed a tendency to increase and high vault showed a tendency to decrease, but not significantly, over time. There was no statistically significant correlation between the amount of vault and the refractive error (Pearson correlation coefficient R=0.111, p=0.473) and there was a statistically significant correlation between the vault and HOAs (R=0.304, p=0.024).
Implantable Collamer lens vault over the crystalline lens had the tendency toward a slight decrease with time and did not significantly affect the vision outcome 1 year after surgery.
研究可植入式Collamer晶状体(ICL)植入术后1年眼房深度的变化及其对视觉效果的影响。
在这项回顾性研究中,对66例接受ICL植入术患者的127只眼在手术前及术后长达1年的时间内进行了检查。检查内容包括白对白(WTW)直径、ICL的中央房深度(ICL后表面与晶状体前表面之间的距离)、屈光不正和波前高阶像差(HOA)。所有统计分析均使用SPSS 13.0软件进行。
观察到房深度在术后1个月内显著下降,此后该值稳定(p = 0.001)。中等房深度在术后3个月后显著下降(配对样本t检验,p < 0.05)。随着时间的推移,低房深度呈增加趋势,高房深度呈下降趋势,但差异均无统计学意义。房深度量与屈光不正之间无统计学显著相关性(Pearson相关系数R = 0.111,p = 0.473),而房深度与高阶像差之间存在统计学显著相关性(R = 0.304,p = 0.024)。
晶状体上方的可植入式Collamer晶状体房深度随时间有轻微下降趋势,且术后1年对视觉效果无显著影响。