The effect of five kinds of plastic catheters (polyvinyl chloride, Teflon, polyurethane, Vialon and siliconized latex) on the phagocytic and bactericidal function of human polymorphonuclear leukocytes was evaluated. In the presence of the polyvinyl chloride, Teflon and siliconized latex catheters, superoxide radical production by polymorphonuclear leukocytes was significantly inhibited. The effect of the siliconized latex catheter was presumably mediated by products eluted from the catheter into the medium, since the incubation of polymorphonuclear leukocytes in eluates obtained from the incubation of this catheter in buffer induced a similar inhibitory effect. This phenomenon was not observed with polyurethane or Vialon catheters. Neither the catheters evaluated nor their eluates affected the uptake of opsonized Staphylococcus aureus by human polymorphonuclear leukocytes. It is concluded that the polyvinyl chloride, Teflon and siliconized latex catheters used in this study could impair the respiratory burst of human polymorphonuclear leukocytes.
评估了五种塑料导管(聚氯乙烯、特氟龙、聚氨酯、维阿隆和硅化乳胶)对人多形核白细胞吞噬和杀菌功能的影响。在聚氯乙烯、特氟龙和硅化乳胶导管存在的情况下,多形核白细胞产生超氧阴离子自由基的能力受到显著抑制。硅化乳胶导管的这种作用可能是由从导管洗脱到培养基中的物质介导的,因为将多形核白细胞在缓冲液中孵育该导管后获得的洗脱液中孵育会产生类似的抑制作用。聚氨酯或维阿隆导管未观察到这种现象。所评估的导管及其洗脱液均未影响人多形核白细胞对调理过的金黄色葡萄球菌的摄取。得出的结论是,本研究中使用的聚氯乙烯、特氟龙和硅化乳胶导管可能会损害人多形核白细胞的呼吸爆发。