Department of Otorhinolaryngology, Goethe University, Frankfurt, Germany.
Otol Neurotol. 2011 Aug;32(6):973-9. doi: 10.1097/MAO.0b013e31822558c4.
To demonstrate the possibility of atraumatic insertion with the free-fitting FLEX electrode by evaluating the degree of hearing preservation postoperatively.
Retrospective study.
Academic tertiary care center.
Twenty-two severely to profoundly hearing impaired subjects with measurable residual hearing preoperatively.
Atraumatic implantation with the 31.5-mm-long, free-fitting, and highly flexible FLEX electrode using either the round window approach or a cochleostomy technique.
Subjects were tested preoperatively in unaided condition and at varying intervals postoperatively. Preoperative and postoperative low-frequency pure-tone average (PTA) and PTA shifts were calculated. Speech perception was measured preoperatively and postoperatively using the Freiburger monosyllabic word test in quiet.
Preoperative low-frequency hearing could be preserved to a certain degree in 77.3% of subjects (17/22) after insertion of the FLEX electrode up to the point of first resistance. Complete loss of residual hearing was observed in 22.7% of subjects (5/22). In 18.2% of the subjects (4/22), the preoperative PTA was preserved within 10 dB. Pure-tone average results between preoperative and most recent testing showed statistically significant differences (p < 0.001 to p = 0.031) for almost all loudness levels ranging from 125 Hz to 1.5 kHz. The maximum threshold shift was 40 dB at 250 Hz for the lower frequencies up to 1 kHz. Monosyllable testing in quiet demonstrated significant improvement over time (p < 0.001).
This study showed that preservation of residual hearing is possible in a high number of subjects when a flexible electrode and atraumatic surgical techniques are used.
通过评估术后听力保留程度,展示使用自由贴合 FLEX 电极进行无创插入的可能性。
回顾性研究。
学术三级护理中心。
22 名术前具有可测量残余听力的重度至极重度听力障碍受试者。
使用 31.5 毫米长、自由贴合、高度灵活的 FLEX 电极,通过圆窗入路或耳蜗造口技术进行无创植入。
受试者在未辅助状态下进行术前测试,并在术后不同时间间隔进行测试。计算术前和术后低频纯音平均(PTA)和 PTA 变化。术前和术后使用 Freiburger 单音节词测试在安静环境下测量言语感知。
在插入 FLEX 电极至第一次阻力的过程中,77.3%(17/22)的受试者能够在一定程度上保留低频听力,22.7%(5/22)的受试者完全丧失残余听力。在 18.2%的受试者(4/22)中,术前 PTA 在 10dB 以内得到保留。纯音平均结果显示,术前和最近一次测试之间在几乎所有响度水平(125Hz 至 1.5kHz)上均存在统计学显著差异(p<0.001 至 p=0.031)。低频最大阈值移位为 250Hz 时为 40dB,最高可达 1kHz。在安静环境下进行的单音节测试显示随着时间的推移有显著改善(p<0.001)。
本研究表明,在使用灵活电极和无创手术技术时,可在大量受试者中保留残余听力。