Suppr超能文献

髓外全膝关节置换术中基于机械轴的股骨假体旋转:股骨横轴线与髁间轴的比较。

Mechanical axis-derived femoral component rotation in extramedullary total knee arthroplasty: a comparison between femoral transverse axis and transepicondylar axis.

机构信息

Department of Orthopaedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Ilwon-Dong, Kangnam-Ku, Seoul, 135-710, Korea.

出版信息

Knee Surg Sports Traumatol Arthrosc. 2012 Mar;20(3):538-45. doi: 10.1007/s00167-011-1597-7. Epub 2011 Jul 13.

Abstract

PURPOSE

Correct rotational alignment of the femoral component is paramount to the success of total knee arthroplasty, but debate continues as to which method is the most reliable. The purpose of this study was to evaluate mechanical axis-derived rotational axis of the femoral component using an extramedullary femoral alignment guide system.

METHODS

Between 2009 and 2010, 60 patients (120 knees) underwent simultaneous bilateral total knee arthroplasty. Postoperative CT scans were performed on all 120 knees. The mechanical axis-derived rotational axis of the femoral component was compared with the surgical transepicondylar axis on CT scans.

RESULTS

The femoral component was externally rotated compared with the surgical transepicondylar axis (mean = 1.6°, SD = 2.2°, range: from 4.8° of internal rotation to 7.9° of external rotation). One hundred and nine of the 120 knees (90.8%) were rotated by less than 5° from the surgical transepicondylar axis. All inter-observer observations on CT scans were within a range of ±2.1° and showed no significant differences.

CONCLUSION

Mechanical axis-derived rotational axis of the femoral component was found to be closely related to the surgical transepicondylar axis, to an extent which suggests that the mechanical axis-derived rotational axis could be a new alternative option in determining optimal rotational alignment of the femoral component during total knee arthroplasty.

LEVEL OF EVIDENCE

II.

摘要

目的

股骨部件的正确旋转对线对于全膝关节置换术的成功至关重要,但哪种方法最可靠仍存在争议。本研究的目的是使用髓外股骨对线引导系统评估股骨部件的机械轴衍生旋转轴。

方法

2009 年至 2010 年期间,60 名患者(120 膝)接受了同期双侧全膝关节置换术。对所有 120 个膝关节进行术后 CT 扫描。比较了股骨部件的机械轴衍生旋转轴与 CT 扫描上的手术髁间轴。

结果

股骨部件相对于手术髁间轴呈外旋(平均值=1.6°,标准差=2.2°,范围:内旋 4.8°至外旋 7.9°)。120 个膝关节中有 109 个(90.8%)的旋转角度小于手术髁间轴的 5°。所有 CT 扫描的观察者间观察值均在±2.1°范围内,无显著差异。

结论

股骨部件的机械轴衍生旋转轴与手术髁间轴密切相关,这表明在全膝关节置换术中,机械轴衍生旋转轴可能是确定股骨部件最佳旋转对线的新选择。