Suppr超能文献

羟基磷灰石涂层对非骨水泥股骨柄生存率的影响。一项瑞典髋关节置换登记研究,涉及 4772 髋。

Effects of hydroxyapatite coating on survival of an uncemented femoral stem. A Swedish Hip Arthroplasty Register study on 4,772 hips.

机构信息

Department of Orthopaedics, Institute of Surgical Sciences, Uppsala University Hospital, Uppsala, Sweden.

出版信息

Acta Orthop. 2011 Aug;82(4):399-404. doi: 10.3109/17453674.2011.597699. Epub 2011 Jul 13.

Abstract

BACKGROUND AND PURPOSE

Hydroxyapatite (HA) is widely used as a coating for uncemented total hip arthroplasty components. This has been suggested to improve implant ingrowth and long-term stability. However, the evidence behind the use of HA coating on femoral stems is ambiguous. We investigated survival of an uncemented, tapered titanium femoral stem that was available either with or without HA coating (Bi-Metric).

PATIENTS AND METHODS

The stem had been used in 4,772 total hip arthroplasties (THAs) in 4,169 patients registered in the Swedish Hip Arthroplasty Register between 1992 and 2009. 59% of the stems investigated were coated with HA and 41% were uncoated. Kaplan-Meier survival analysis and a Cox regression model with adjustment for age, sex, primary diagnosis, and the type of cup fixation were used to calculate survival rates and adjusted risk ratios (RRs) of the risk of revision for various reasons.

RESULTS

The 10-year survival rates of the HA-coated version and the uncoated version were about equal when we used revision for any reason as the endpoint: 98% (95% CI: 98-99) and 98% (CI: 97-99), respectively. A Cox regression model adjusting for the covariates mentioned above showed that the presence of HA coating did not have any influence on the risk of stem revision for any reason (RR = 1.0, 95% CI: 0.6-1.6) or due to aseptic loosening (RR = 0.5, CI: 0.2-1.5). There was no effect of HA coating on the risk of stem revision due to infection, dislocation, or fracture.

INTERPRETATION

The uncemented Bi-Metric stem showed excellent 10-year survival. Our findings do not support the use of HA coating on this stem to enhance implant survival.

摘要

背景与目的

羟基磷灰石(HA)广泛用作非骨水泥全髋关节置换术组件的涂层。这被认为可以改善植入物的生长和长期稳定性。然而,关于股骨柄上使用 HA 涂层的证据尚不清楚。我们研究了一种非骨水泥、锥形钛股骨柄的存活率,该柄有或没有 HA 涂层(Bi-Metric)。

患者和方法

1992 年至 2009 年期间,在瑞典髋关节置换登记处登记的 4169 名患者的 4772 例全髋关节置换术中使用了该柄。调查的柄中有 59%涂有 HA,41%未涂。使用 Kaplan-Meier 生存分析和 Cox 回归模型,调整年龄、性别、主要诊断和杯固定类型,计算各种原因的翻修生存率和调整后的风险比(RR)。

结果

当我们将任何原因的翻修为终点时,HA 涂层版本和未涂层版本的 10 年生存率几乎相等:98%(95%CI:98-99)和 98%(CI:97-99)。调整上述协变量的 Cox 回归模型显示,HA 涂层的存在对任何原因的翻修风险(RR=1.0,95%CI:0.6-1.6)或无菌性松动(RR=0.5,CI:0.2-1.5)没有任何影响。HA 涂层对感染、脱位或骨折导致的柄翻修风险没有影响。

结论

非骨水泥 Bi-Metric 柄显示出优异的 10 年生存率。我们的研究结果不支持在该柄上使用 HA 涂层来提高植入物的存活率。