Suppr超能文献

2 年后从人下颌骨中取出的即刻负载种植体的组织形态计量学评估。

Histomorphometric evaluation of an immediately loaded implant retrieved from human mandible after 2 years.

机构信息

EIS-international educational society and private practice, San Benedetto del Tronto, Italy.

出版信息

Int J Immunopathol Pharmacol. 2011 Apr-Jun;24(2 Suppl):31-6. doi: 10.1177/03946320110240S207.

Abstract

The aim of the present study was to evaluate the interplay between microstructure and function of the bone around an immediately loaded implant retrieved from human maxilla after 23 months due to fracture. A spiral implant of 3.3 mm x 15 mm was placed in a male 53 years old in the anterior region of the mandible bone (4.1) and it was processed for histology. The specimen was analyzed under the confocal scanning laser microscope (CSLM) and brightfield light microscope (LM) equipped with circularly polarized light (CPL). The BIC rate was 76.7 ± 4.9 (mean ±SD). Many cement lines indicates an high remodeling rate of the bone. The transverse collagen fiber orientation (CFO) (mean±SD) under the lower flank of the thread near the tread tip was 55.2 ± 4.8 x 10(4) pixel while the longitudinal CFO was 45.8 ± 2.3 x 10(4) pixel (P<.05). In the inter-threads region the transverse CFO (mean ±SD) was 36.4 ± 2.4 x 10(4) pixel while the longitudinal CFO was 65.6 ± 6.5 x 10(4) pixel (P<.05). The osteocytes numbers (mean ±SD) was 205 ± 45 in the peri-implant bone and 144 ± 53 in the native bone (P=.007). After 2-years of loading the SLA spiral implant was well osseointegrated but still surrounded by woven bone. The osteocytes density was significantly higher in the peri-implant bone than in the native bone. The transverse collagen fibers were significantly associated with the lower flank of the implant threads, while the longitudinal collagen fibers were more represented in the straight surface of the implant. The implant fracture was correlated to crestal bone resorbing and subsequent fatigue yielding.

摘要

本研究旨在评估因骨折而从上颌骨中取出的、在植入后 23 个月时即刻负重的种植体周围骨的微观结构与功能之间的相互作用。将 3.3mm x 15mm 的螺旋种植体植入一名 53 岁男性下颌骨前区(4.1),并对其进行组织学处理。标本在共聚焦扫描激光显微镜(CSLM)和配备圆偏振光(CPL)的明场显微镜(LM)下进行分析。BIC 率为 76.7 ± 4.9(平均值 ±SD)。许多骨水泥线表明骨的高改建率。在螺纹根部附近螺纹下侧的横向胶原纤维取向(CFO)(平均值 ±SD)为 55.2 ± 4.8 x 10(4)像素,而纵向 CFO 为 45.8 ± 2.3 x 10(4)像素(P<.05)。在螺纹间区域,横向 CFO(平均值 ±SD)为 36.4 ± 2.4 x 10(4)像素,而纵向 CFO 为 65.6 ± 6.5 x 10(4)像素(P<.05)。种植体周围骨中的骨细胞数量(平均值 ±SD)为 205 ± 45,原生骨中的骨细胞数量为 144 ± 53(P=.007)。在负重 2 年后,SLA 螺旋种植体已很好地骨整合,但仍被编织骨包围。种植体周围骨中的骨细胞密度明显高于原生骨。横向胶原纤维与种植体螺纹的下侧明显相关,而纵向胶原纤维在种植体的直表面上更为突出。种植体骨折与牙槽骨吸收和随后的疲劳屈服有关。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验