OBJECTIVES

In the past several scoring systems were proposed for early human development aiming to assist in the identification of the best embryos. Scoring criteria are usually assessed at static developmental time points by microscopy. For almost every scoring system controversial results on its benefit can be found in the literature. With the introduction of time-lapse imaging static assessment of developmental parameters needs to be revised. The objective of this study was to critical review the strategy of static assessment by using an embryo monitoring system to study time-dependent variations of scoring criteria.

STUDY DESIGN

Human oocytes were subjected to intracytoplasmic sperm injection and subsequently incubated in an embryo monitoring device. Images from individual oocytes were captured at given time intervals allowing a time-lapse analysis of early embryo development.

MAIN OUTCOME MEASURES

Scoring of pronuclear morphology, early cleavage and embryo morphology up to day 3 of development was performed at standard time points and compared to the morphological fate present in time intervals prior and after standard assessment.

RESULTS

Pronuclear morphology showed a high variability within very short time intervals. First cleavage can be observed at very early time points questioning the criterion "early cleavage". Embryo morphology can change within short time intervals and thus may be misleading if assessment is done at a static time point.

CONCLUSIONS

Scoring of early embryo development has limitations if based on static observation only. Time-lapse imaging will lead to revised scoring systems emphasizing the need for a new look on embryological parameters.

摘要

目的

过去提出了几种胚胎早期发育评分系统,旨在帮助识别最佳胚胎。评分标准通常通过显微镜在静态发育时间点进行评估。对于几乎每一种评分系统,文献中都可以找到关于其益处的有争议的结果。随着时间推移成像的引入,对发育参数的静态评估需要进行修订。本研究的目的是通过使用胚胎监测系统来研究评分标准的时间依赖性变化,对静态评估策略进行批判性回顾。

研究设计

将人卵母细胞进行胞浆内单精子注射,然后在胚胎监测设备中孵育。在特定的时间间隔捕获来自单个卵母细胞的图像,允许对早期胚胎发育进行时间推移分析。

主要观察指标

在标准时间点对原核形态、早期卵裂和胚胎形态进行评分,并与标准评估前后时间间隔内的形态命运进行比较。

结果

原核形态在非常短的时间间隔内表现出高度的可变性。早期卵裂可以在非常早的时间点观察到,这对“早期卵裂”的标准提出了质疑。胚胎形态可以在短时间间隔内发生变化,如果在静态时间点进行评估,可能会产生误导。

结论

如果仅基于静态观察,对早期胚胎发育的评分存在局限性。时间推移成像将导致修订后的评分系统,强调需要对胚胎学参数进行新的研究。