Zhou Qin, Liu Zhiling, Li Chuanfu, Qu Chuncheng, Ni Shilei, Zeng Qingshi
Department of Radiology, Qilu Hospital of Shandong University, China.
Acta Radiol. 2011 Oct 1;52(8):894-8. doi: 10.1258/ar.2011.110195. Epub 2011 Aug 11.
Microvascular decompression is an etiological strategy for the therapy of trigeminal neuralgia (TN). Preoperative identification of neurovascular compression, therefore, could have an impact on the determination of appropriate treatment for TN.
To evaluate the value of contrast-enhanced and unenhanced three-dimensional (3D) time-of-flight (TOF) MR angiography in the visualization of neurovascular relationship in patients with TN.
Thirty-seven patients with unilateral TN underwent unenhanced and contrast-enhanced 3D TOF MR angiography with a 3.0-T MR system. Images were reviewed by a radiologist blinded to clinical details. Vascular contact with the trigeminal nerve was identified, and the nature of the involved vessels (artery or vein) was determined. All patients underwent microvascular decompression.
In 37 patients with TN, contrast-enhanced 3D TOF MR angiography identified surgically verified neurovascular contact in 35 of 36 symptomatic nerves, and there was no false-positive. Based on surgical findings, the sensitivity of MR imaging was 97.2% and specificity 100%. The nature of the offending vessel was correctly identified in 94.4% of the patients by using the combination of contrast-enhanced and unenhanced MR angiography.
Contrast-enhanced 3D TOF MR angiography is useful in the detection of vascular contact with the trigeminal nerve in patients with TN, and this MR imaging in combination with unenhanced MR angiography could help in the identification of the nature of the responsible vessels.
微血管减压术是治疗三叉神经痛(TN)的一种病因学治疗策略。因此,术前识别神经血管压迫可能会影响TN合适治疗方案的确定。
评估对比增强和非增强三维(3D)时间飞跃(TOF)磁共振血管造影在TN患者神经血管关系可视化中的价值。
37例单侧TN患者使用3.0-T磁共振系统进行了非增强和对比增强3D TOF磁共振血管造影。由对临床细节不知情的放射科医生对图像进行评估。识别与三叉神经的血管接触,并确定受累血管(动脉或静脉)的性质。所有患者均接受了微血管减压术。
在37例TN患者中,对比增强3D TOF磁共振血管造影在36条有症状神经中的35条中识别出经手术证实的神经血管接触,且无假阳性。根据手术结果,磁共振成像的敏感性为97.2%,特异性为100%。通过联合使用对比增强和非增强磁共振血管造影,94.4%的患者正确识别了肇事血管的性质。
对比增强3D TOF磁共振血管造影有助于检测TN患者中与三叉神经的血管接触,且这种磁共振成像与非增强磁共振血管造影相结合有助于识别责任血管的性质。