Suppr超能文献

采用三维快速低角度激发(3D-FLASH)和三维稳态构成干扰序列(3D-CISS)磁共振成像对三叉神经痛患者神经血管关系进行术前评估。

Preoperative evaluation of neurovascular relationship in trigeminal neuralgia by three-dimensional fast low angle shot (3D-FLASH) and three-dimensional constructive interference in steady-state (3D-CISS) MRI sequence.

作者信息

Yang Dengfa, Shen Jianmin, Xia Xianwu, Lin Yeqing, Yang Tiejun, Lin Hanshun, Jin Yong, Zhou Kaiyu, Li Youcheng

机构信息

1 Department of Radiology, Taizhou Municipal Hospital , Taizhou, Zhejiang , China.

2 Department of Neurological Surger, Taizhou Municipal Hospital , Taizhou, Zhejiang , China.

出版信息

Br J Radiol. 2018 May;91(1085):20170557. doi: 10.1259/bjr.20170557. Epub 2018 Feb 13.

Abstract

OBJECTIVE

The purpose of the study was to evaluate the value of high-resolution three-dimensional fast low angle shot (3D-FLASH) and three-dimensional constructive interference in steady-state (3D-CISS) MRI sequence solely or the combination of both in the visualization of neurovascular relationship in patients with trigeminal neuralgia (TN).

METHODS

65 patients with unilateral TN underwent 3D-FLASH and 3D-CISS imaging were retrospectively studied. Neurovascular relationship at the intracisternal segment of trigeminal nerve was reviewed by two experienced neuroradiologist, who was blinded to the clinical details. The imaging results were compared with the operative findings in all patients.

RESULTS

The accuracy and positive rates of the 3D-FLASH + CISS imaging (98.46, 92.31%) in judging the symptomatic side according to the presence of vascular contacts were higher than those of 3D-CISS (90.77%, 84.62) or 3D-FLASH (89.23, 83.08%) sequence. In addition, the statistical analysis showed the sensitivity and accuracy of 3D-FLASH + CISS imaging was higher than that of 3D-FLASH (p < 0.05). The 3D-FLASH + CISS imaging was more accurate in determining the type of offending vessel than 3D-CISS or 3D-FLASH imaging.

CONCLUSION

The retrospective study demonstrates that the combination of 3D-FLASH with 3D-CISS sequence well delineates the relationship between intracisternal segment of trigeminal nerve and adjacent vessels in terms of increased positive rates and accuracy. Advances in knowledge: The study firstly dealt with the combination of 3D-CISS and 3D-FLASH imaging in TN.

摘要

目的

本研究旨在评估高分辨率三维快速低角度激发(3D-FLASH)和三维稳态构成干扰(3D-CISS)磁共振成像(MRI)序列单独使用或两者联合使用在三叉神经痛(TN)患者神经血管关系可视化中的价值。

方法

对65例单侧TN患者进行3D-FLASH和3D-CISS成像的回顾性研究。由两名经验丰富的神经放射科医生对三叉神经脑池段的神经血管关系进行评估,他们对临床细节不知情。将所有患者的成像结果与手术结果进行比较。

结果

3D-FLASH + CISS成像根据血管接触情况判断症状侧的准确率(98.46%)和阳性率(92.31%)高于3D-CISS(90.77%,84.62%)或3D-FLASH(89.23%,83.08%)序列。此外,统计分析显示3D-FLASH + CISS成像的敏感性和准确性高于3D-FLASH(p < 0.05)。3D-FLASH + CISS成像在确定责任血管类型方面比3D-CISS或3D-FLASH成像更准确。

结论

这项回顾性研究表明,3D-FLASH与3D-CISS序列联合使用能更好地描绘三叉神经脑池段与相邻血管之间的关系,提高阳性率和准确性。知识进展:该研究首次探讨了3D-CISS和3D-FLASH成像在TN中的联合应用。

相似文献

引用本文的文献

本文引用的文献

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验