Suppr超能文献

7.0特斯拉下颅内穿支血管的高分辨率对比剂增强磁共振血管造影时间飞跃成像

High-resolution postcontrast time-of-flight MR angiography of intracranial perforators at 7.0 Tesla.

作者信息

Harteveld Anita A, De Cocker Laurens J L, Dieleman Nikki, van der Kolk Anja G, Zwanenburg Jaco J M, Robe Pierre A, Luijten Peter R, Hendrikse Jeroen

机构信息

Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands.

Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands; Image Sciences Institute, University Medical Center Utrecht, Utrecht, The Netherlands.

出版信息

PLoS One. 2015 Mar 16;10(3):e0121051. doi: 10.1371/journal.pone.0121051. eCollection 2015.

Abstract

BACKGROUND AND PURPOSE

Different studies already demonstrated the benefits of 7T for precontrast TOF-MRA in the visualization of intracranial small vessels. The aim of this study was to assess the performance of high-resolution 7T TOF-MRA after the administration of a gadolinium-based contrast agent in visualizing intracranial perforating arteries.

MATERIALS AND METHODS

Ten consecutive patients (7 male; mean age, 50.4 ± 9.9 years) who received TOF-MRA at 7T after contrast administration were retrospectively included in this study. Intracranial perforating arteries, branching from the parent arteries of the circle of Willis, were identified on all TOF-MRA images. Provided a TOF-MRA before contrast administration was present, a direct comparison between pre- and postcontrast TOF-MRA was made.

RESULTS

It was possible to visualize intracranial perforating arteries branching off from the entire circle of Willis, and their proximal branches. The posterior cerebral artery (P1 and proximal segment of P2) appeared to have the largest number of visible perforating branches (mean of 5.1 in each patient, with a range of 2-7). The basilar artery and middle cerebral artery (M1 and proximal segment M2) followed with a mean number of 5.0 and 3.5 visible perforating branches (range of 1-9 and 1-8, respectively). Venous contamination in the postcontrast scans sometimes made it difficult to discern the arterial or venous nature of a vessel.

CONCLUSION

High-resolution postcontrast TOF-MRA at 7T was able to visualize multiple intracranial perforators branching off from various parts of the circle of Willis and proximal intracranial arteries. Although confirmation in a larger study is needed, the administration of a contrast agent for high-resolution TOF-MRA at 7T seems to enable a better visualization of the distal segment of certain intracranial perforators.

摘要

背景与目的

不同研究已证实7T磁共振成像(MRI)在对比剂增强前的时间飞跃法磁共振血管造影(TOF-MRA)中对颅内小血管可视化的益处。本研究旨在评估基于钆的对比剂注射后高分辨率7T TOF-MRA在颅内穿支动脉可视化方面的性能。

材料与方法

本研究回顾性纳入了10例连续接受对比剂注射后7T TOF-MRA检查的患者(7例男性;平均年龄50.4±9.9岁)。在所有TOF-MRA图像上识别从 Willis 环的母动脉分支出来的颅内穿支动脉。若有对比剂注射前的TOF-MRA图像,则对对比剂注射前后的TOF-MRA进行直接比较。

结果

能够可视化从整个 Willis 环分支出来的颅内穿支动脉及其近端分支。大脑后动脉(P1段和P2段近端)的可见穿支分支数量似乎最多(每位患者平均5.1支,范围为2 - 7支)。基底动脉和大脑中动脉(M1段和M2段近端)的可见穿支分支平均数分别为5.0支和3.5支(范围分别为1 - 9支和1 - 8支)。对比剂注射后的扫描中静脉污染有时会使区分血管的动脉或静脉性质变得困难。

结论

7T高分辨率对比剂增强后的TOF-MRA能够可视化从 Willis 环各部位和颅内近端动脉分支出来的多个颅内穿支。尽管需要更大规模研究的证实,但对于7T高分辨率TOF-MRA注射对比剂似乎能更好地显示某些颅内穿支的远端节段。