From University of Applied Sciences, Jena, Germany.
J Refract Surg. 2011 Aug;27(8):602-12. doi: 10.3928/1081597X-20110317-02.
To investigate effects of optical aberration correction on vision with glare.
Correction of aberrations up to the 6th Zernike order (closed-loop correction) was compared with conventional spectacle correction in 42 healthy eyes. To create these corrections, an adaptive optics system including a thin-film transistor (TFT) monitor for displaying optotypes with additional glare sources was used. Employing both corrections, visual acuity and contrast sensitivity (CS) were tested alternately with and without glare. Disability glare was computed as the difference between log CS without and with glare. Individuals were also asked to rate subjectively the quality of three images displayed on the TFT monitor.
Significant improvements of CS without and with glare were found with the closed-loop correction (0.147 and 0.198 log CS, respectively), whereas no significant difference in visual acuity was found in either correction. Correlations were determined between reduction of total root-mean-square error and increase of CS with glare (Pearson correlation coefficient r=0.42) and decrease of disability glare (r=-0.33). Visual acuity was correlated with the visual Strehl ratio based on the optical transfer function (r=0.46). Subjective comparison of the images showed improvements more clearly. Depending on the image, in 57% to 78% of the eyes, closed-loop correction was rated better than spectacle correction. The subjective glare effect was reduced as well.
Investigation of vision with glare seems to be a reasonable additional test to evaluate the visual outcome of a customized correction.
研究像差矫正对视功能眩光的影响。
对 42 只健康眼,采用第 6 阶泽尼克像差矫正(闭环矫正)与常规眼镜矫正比较,创建这些矫正,采用了包括薄膜晶体管(TFT)显示器的自适应光学系统,用于显示带有附加眩光源的视力表。两种矫正方式交替进行视力和对比敏感度(CS)测试,同时有无眩光。计算光致失能眩光作为无眩光和有眩光时 CS 的对数差。还要求个体对 TFT 监视器上显示的三个图像的质量进行主观评价。
闭环矫正显著提高了无眩光和有眩光时的 CS(分别为 0.147 和 0.198 log CS),而两种矫正方式的视力均无显著差异。总均方根误差减少与 CS 增加与眩光呈正相关(Pearson 相关系数 r=0.42)和光致失能眩光减少(r=-0.33)。视力与基于光学传递函数的视觉斯特雷尔比相关(r=0.46)。主观图像比较显示改善更为明显。根据图像,57%至 78%的眼,闭环矫正优于眼镜矫正。主观眩光效应也降低。
眩光视功能的研究似乎是评估定制矫正视觉结果的合理附加测试。