Faculty of Health Studies, University of Ljubljana, Ljubljana, Slovenia.
Int J Biometeorol. 2012 Sep;56(5):811-21. doi: 10.1007/s00484-011-0483-9. Epub 2011 Aug 21.
Determination of the thermal thresholds is used clinically for evaluation of peripheral nervous system function. The aim of this study was to evaluate reliability of the method of levels performed with a new, low cost device for determining cutaneous temperature sensitivity. Nineteen male subjects were included in the study. Thermal thresholds were tested on the right side at the volar surface of mid-forearm, lateral surface of mid-upper arm and front area of mid-thigh. Thermal testing was carried out by the method of levels with an initial temperature step of 2°C. Variability of thermal thresholds was expressed by means of the ratio between the second and the first testing, coefficient of variation (CV), coefficient of repeatability (CR), intraclass correlation coefficient (ICC), mean difference between sessions (S1-S2diff), standard error of measurement (SEM) and minimally detectable change (MDC). There were no statistically significant changes between sessions for warm or cold thresholds, or between warm and cold thresholds. Within-subject CVs were acceptable. The CR estimates for warm thresholds ranged from 0.74°C to 1.06°C and from 0.67°C to 1.07°C for cold thresholds. The ICC values for intra-rater reliability ranged from 0.41 to 0.72 for warm thresholds and from 0.67 to 0.84 for cold thresholds. S1-S2diff ranged from -0.15°C to 0.07°C for warm thresholds, and from -0.08°C to 0.07°C for cold thresholds. SEM ranged from 0.26°C to 0.38°C for warm thresholds, and from 0.23°C to 0.38°C for cold thresholds. Estimated MDC values were between 0.60°C and 0.88°C for warm thresholds, and 0.53°C and 0.88°C for cold thresholds. The method of levels for determining cutaneous temperature sensitivity has acceptable reliability.
热阈值的测定用于评估周围神经系统的功能。本研究旨在评估一种新的低成本设备用于测定皮肤温度敏感性的水平测定方法的可靠性。19 名男性受试者纳入本研究。在右侧前臂掌侧、上臂外侧和大腿前区进行热阈值测试。热测试采用初始温度步长为 2°C 的水平测定法进行。通过第二次与第一次测试的比值、变异系数(CV)、可重复性系数(CR)、组内相关系数(ICC)、两次测试之间的平均值差异(S1-S2diff)、测量标准误差(SEM)和最小可检测变化(MDC)来表示热阈值的变异性。在温暖或寒冷阈值或温暖和寒冷阈值之间,各次测试之间没有统计学上的显著变化。个体内 CV 是可以接受的。温热阈值的 CR 估计值范围为 0.74°C 至 1.06°C,冷阈值的 CR 估计值范围为 0.67°C 至 1.07°C。对于温热阈值,内部评价者可靠性的 ICC 值范围为 0.41 至 0.72,对于寒冷阈值,ICC 值范围为 0.67 至 0.84。S1-S2diff 温热阈值范围为-0.15°C 至 0.07°C,冷阈值范围为-0.08°C 至 0.07°C。SEM 温热阈值范围为 0.26°C 至 0.38°C,冷阈值范围为 0.23°C 至 0.38°C。估计的 MDC 值温热阈值在 0.60°C 至 0.88°C 之间,冷阈值在 0.53°C 至 0.88°C 之间。用于测定皮肤温度敏感性的水平测定法具有可接受的可靠性。