Suppr超能文献

数字全景片下颌骨髁突的计算测量的可靠性。

Reliability of computational measurement of the condyles on digital panoramic radiographs.

机构信息

Department of Surgery, University Hospital and Faculty of Medicine of Geneva, 1211 Genève - Switzerland.

出版信息

Dentomaxillofac Radiol. 2011 Oct;40(7):444-50. doi: 10.1259/dmfr/83507370.

Abstract

OBJECTIVE

The aim of this study was to evaluate the reliability of a computational method for assessing three condylar measurements on digital panoramic radiographs: condylar height, area and perimeter.

METHODS

A computer calculation of the area, the perimeter and the height of 34 condyles was determined on digital panoramic radiographs taken from 17 patients. The test-retest precision of measurements calculation was estimated using an intraclass correlation coefficient (ICC) and Dahlberg's formula at 2 week intervals on the same radiograph to assess intraobserver precision and on two radiographs (RX1 and RX2) to assess the radiographic procedure precision. Changes between measurements on RX1 and RX2 were estimated using paired t-tests to detect systematic errors.

RESULTS

Precision of all indices was very high when measurements were made on the same radiograph, thus confirming good reliability for the present computational measuring method. The precision was lower when two different radiographs were compared but was still within an acceptable range of tolerance. There were no statistically significant changes in condylar area, perimeter or height values between RX1 and RX2.

CONCLUSIONS

This study has demonstrated that (1) the height of the condyle can be rapidly and reliably assessed using a specific computer system directly on digital panoramic radiographs; (2) although less reliable, area and perimeter can also be acceptably evaluated; and (3) this method has the potential for being routinely used to monitor changes in clinical follow-up as well as for research purposes.

摘要

目的

本研究旨在评估一种在数字化全景片上评估三个髁突测量值的计算方法的可靠性:髁突高度、面积和周长。

方法

对 17 名患者的数字化全景片进行了 34 个髁突的面积、周长和高度的计算机计算。使用组内相关系数(ICC)和 Dahlberg 公式在同一放射片中以 2 周的间隔评估测量计算的测试-再测试精度,以评估观察者内精度,并在两张放射片(RX1 和 RX2)上评估放射程序精度。使用配对 t 检验估计 RX1 和 RX2 之间测量值的变化,以检测系统误差。

结果

当在同一张放射片上进行测量时,所有指标的精度都非常高,这证实了目前计算测量方法的可靠性非常高。当比较两张不同的放射片时,精度会降低,但仍在可接受的容差范围内。RX1 和 RX2 之间的髁突面积、周长或高度值没有统计学上的显著变化。

结论

本研究表明:(1)可以使用特定的计算机系统直接在数字化全景片上快速可靠地评估髁突的高度;(2)尽管可靠性较低,但面积和周长也可以进行可接受的评估;(3)该方法有可能常规用于监测临床随访以及研究目的的变化。

相似文献

引用本文的文献

本文引用的文献

2
A new method of assessing the size of mandibular cysts on orthopantomograms: projection area fraction.
J Craniofac Surg. 2009 Nov;20(6):2020-3. doi: 10.1097/SCS.0b013e3181bd302e.
4
Contemporary imaging of the temporomandibular joint.颞下颌关节的当代影像学
Dent Clin North Am. 2008 Oct;52(4):875-90, viii. doi: 10.1016/j.cden.2008.06.001.
5
The precision of the panoramic mandibular index.全景下颌指数的精确性。
Dentomaxillofac Radiol. 2006 Nov;35(6):442-6. doi: 10.1259/dmfr/25346328.
6
Validity of panoramic radiographs for measuring mandibular asymmetry.全景X线片测量下颌不对称的有效性
Angle Orthod. 2006 May;76(3):388-93. doi: 10.1043/0003-3219(2006)076[0388:VOPRFM]2.0.CO;2.
9
Evaluation of the precision of dimensional measurements of the mandible on panoramic radiographs.全景X线片上下颌骨尺寸测量精度的评估。
Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 1998 Aug;86(2):242-8. doi: 10.1016/s1079-2104(98)90132-9.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验