Comparison of use of an infrared anesthetic gas monitor and refractometry for measurement of anesthetic agent concentrations.

作者信息

Ambrisko Tamas D, Klide Alan M

机构信息

Department of Clinical Studies, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA.

出版信息

Am J Vet Res. 2011 Oct;72(10):1299-304. doi: 10.2460/ajvr.72.10.1299.

DOI:10.2460/ajvr.72.10.1299
PMID:21962271
Abstract

OBJECTIVE

To assess agreement between anesthetic agent concentrations measured by use of an infrared anesthetic gas monitor (IAGM) and refractometry. SAMPLE-4 IAGMs of the same type and 1 refractometer.

PROCEDURES

Mixtures of oxygen and isoflurane, sevoflurane, desflurane, or N(2)O were used. Agent volume percent was measured simultaneously with 4 IAGMs and a refractometer at the common gas outlet. Measurements obtained with each of the 4 IAGMs were compared with the corresponding refractometer measurements via the Bland-Altman method. Similarly, Bland-Altman plots were also created with either IAGM or refractometer measurements and desflurane vaporizer dial settings.

RESULTS

Bias ± 2 SD for comparisons of IAGM and refractometer measurements was as follows: isoflurane, -0.03 ± 0.18 volume percent; sevoflurane, -0.19 ± 0.23 volume percent; desflurane, 0.43 ± 1.22 volume percent; and N(2)O, -0.21 ± 1.88 volume percent. Bland-Altman plots comparing IAGM and refractometer measurements revealed nonlinear relationships for sevoflurane, desflurane, and N(2)O. Desflurane measurements were notably affected; bias ± limits of agreement (2 SD) were small (0.1 ± 0.22 volume percent) at < 12 volume percent, but both bias and limits of agreement increased at higher concentrations. Because IAGM measurements did not but refractometer measurements did agree with the desflurane vaporizer dial settings, infrared measurement technology was a suspected cause of the nonlinear relationships.

CONCLUSIONS AND CLINICAL RELEVANCE

Given that the assumption of linearity is a cornerstone of anesthetic monitor calibration, this assumption should be confirmed before anesthetic monitors are used in experiments.

摘要

相似文献

1
Comparison of use of an infrared anesthetic gas monitor and refractometry for measurement of anesthetic agent concentrations.
Am J Vet Res. 2011 Oct;72(10):1299-304. doi: 10.2460/ajvr.72.10.1299.
2
Comparison of an infrared anaesthetic agent analyser (Datex-Ohmeda) with refractometry for measurement of isoflurane, sevoflurane and desflurane concentrations.用于测量异氟烷、七氟烷和地氟烷浓度的红外麻醉剂分析仪(Datex-Ohmeda)与折射测定法的比较。
Vet Anaesth Analg. 2014 Jul;41(4):386-92. doi: 10.1111/vaa.12118. Epub 2013 Dec 16.
3
Accuracy of isoflurane, halothane, and sevoflurane vaporizers during high oxygen flow and at maximum vaporizer dial setting.异氟烷、氟烷和七氟烷蒸发器在高氧流量及蒸发器刻度盘最大设定值时的准确性。
Am J Vet Res. 2011 Jun;72(6):751-6. doi: 10.2460/ajvr.72.6.751.
4
Evaluation of isoflurane and sevoflurane vaporizers over a wide range of oxygen flow rates.在广泛的氧气流速范围内对异氟烷和七氟烷蒸发器进行评估。
Am J Vet Res. 2006 Jun;67(6):936-40. doi: 10.2460/ajvr.67.6.936.
5
Global warming potential of inhaled anesthetics: application to clinical use.吸入麻醉剂的全球变暖潜能:临床应用。
Anesth Analg. 2010 Jul;111(1):92-8. doi: 10.1213/ANE.0b013e3181e058d7. Epub 2010 Jun 2.
6
Pollution of ambient air by volatile anesthetics: a comparison of 4 anesthetic management techniques.挥发性麻醉剂对环境空气的污染:四种麻醉管理技术的比较
AANA J. 2006 Apr;74(2):121-5.
7
Clinically relevant concentration determination of inhaled anesthetics (halothane, isoflurane, sevoflurane, and desflurane) by 19F NMR.通过19F核磁共振技术测定吸入性麻醉剂(氟烷、异氟烷、七氟烷和地氟烷)的临床相关浓度。
Cell Biochem Biophys. 2008;52(1):31-5. doi: 10.1007/s12013-008-9022-7. Epub 2008 Aug 22.
8
[Evaluation of vaporizers by anesthetic gas monitors corrected with a new method for preparation of calibration gases].
Masui. 1996 Nov;45(11):1354-66.
9
Measurement of anesthetics in blood using a conventional infrared clinical gas analyzer.使用传统红外临床气体分析仪测量血液中的麻醉剂。
Anesth Analg. 2007 Sep;105(3):680-7. doi: 10.1213/01.ane.0000278126.94161.33.
10
Determination of anaesthetic agent concentration by refractometry.
Br J Anaesth. 1995 Jan;74(1):85-8. doi: 10.1093/bja/74.1.85.