Abstract

OBJECTIVE

To clinically evaluate the alignment efficiency of 0.016-inch coaxial superelastic nickel-titanium (NiTi) and 0.016-inch superelastic NiTi in the lower anterior region over a period of 12 weeks.

MATERIALS AND METHODS

A sample of 24 patients requiring lower anterior alignment were included in this single-center, single-operator, double-blind clinical trial and were randomly allocated into two groups of 12 patients. The type of wire selected for each patient was not disclosed to the provider or to the patient. Comparison of pretreatment characteristics of the archwire groups revealed no discrimination between two samples, thus verifying the random allocation of the intervention. An initial alginate impression of the lower arch was followed by impressions at 4-, 8-, and 12-week intervals. Casts were measured using the coordinate measuring machine to denote the degree of alignment. Duplicate readings of the cast series were taken to assess measurement variation.

RESULTS

A statistically significant difference (P < .05) in the mean values of tooth movement demonstrated the superior aligning efficiency of coaxial superelastic NiTi over single-stranded superelastic NiTi in relieving lower anterior crowding. The measurement error recorded was within acceptable limits, with range values within 95% limits of agreement.

CONCLUSION

Coaxial superelastic NiTi wire proved superior to single-stranded NiTi in its efficiency in relieving lower anterior crowding over a 12-week period.

摘要

目的

临床评估 0.016 英寸同轴超弹性镍钛(NiTi)和 0.016 英寸超弹性 NiTi 在 12 周内在下前牙区的排齐效率。

材料和方法

本单中心、单操作、双盲临床试验纳入 24 例需要下前牙排齐的患者,随机分为两组,每组 12 例。每位患者选择的弓丝类型不向医生或患者透露。对弓丝组的预处理特征进行比较,发现两组之间没有差异,从而验证了干预措施的随机分配。首先对下牙弓进行初始藻酸盐印模,然后在 4、8 和 12 周间隔进行印模。使用坐标测量机测量牙模以表示排齐程度。对牙模系列进行重复读数以评估测量变化。

结果

牙齿移动的平均值存在统计学显著差异(P<.05),表明同轴超弹性 NiTi 在缓解下前牙拥挤方面的排齐效率优于单股超弹性 NiTi。记录的测量误差在可接受范围内,范围值在 95%一致性界限内。

结论

在 12 周的时间内,同轴超弹性 NiTi 丝在缓解下前牙拥挤方面的效率优于单股 NiTi。

相似文献

4
Initial arch wires used in orthodontic treatment with fixed appliances.固定矫治器正畸治疗中初始弓丝的应用。
Cochrane Database Syst Rev. 2024 Feb 6;2(2):CD007859. doi: 10.1002/14651858.CD007859.pub5.
6
Initial arch wires used in orthodontic treatment with fixed appliances.固定矫治器正畸治疗中使用的初始弓丝。
Cochrane Database Syst Rev. 2018 Jul 31;7(7):CD007859. doi: 10.1002/14651858.CD007859.pub4.

引用本文的文献

2
Initial arch wires used in orthodontic treatment with fixed appliances.固定矫治器正畸治疗中初始弓丝的应用。
Cochrane Database Syst Rev. 2024 Feb 6;2(2):CD007859. doi: 10.1002/14651858.CD007859.pub5.
5
Orthodontic treatment for crowded teeth in children.儿童牙齿拥挤的正畸治疗。
Cochrane Database Syst Rev. 2021 Dec 31;12(12):CD003453. doi: 10.1002/14651858.CD003453.pub2.
9
Initial arch wires used in orthodontic treatment with fixed appliances.固定矫治器正畸治疗中使用的初始弓丝。
Cochrane Database Syst Rev. 2018 Jul 31;7(7):CD007859. doi: 10.1002/14651858.CD007859.pub4.

本文引用的文献

3
A systematic review of clinical trials of aligning archwires.对排齐弓丝临床试验的系统评价。
J Orthod. 2009 Mar;36(1):42-51; discussion 15. doi: 10.1179/14653120722914.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验