传统直丝弓矫治器与直丝弓钛合金矫治器系统的形变及扭矩表达比较。

Comparison of deformation and torque expression of the orthos and orthos Ti bracket systems.

作者信息

Melenka Garrett W, Lacoursiere Ryan A, Carey Jason P, Nobes David S, Heo Giseon, Major Paul W

机构信息

Department of Mechanical Engineering, Faculty of Engineering.

Department of Dentistry, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, Canada.

出版信息

Eur J Orthod. 2014 Aug;36(4):381-8. doi: 10.1093/ejo/cjr120. Epub 2011 Oct 19.

Abstract

Orthodontic torque expression is the result of axial rotation of rectangular archwires within a rectangular bracket slot. This study investigates the effect of bracket material on torque expression. Torque exerted by a rotating archwire on each bracket will be measured as well as the relative deformation of each bracket slot. A total of 60 tests were performed where archwires were rotated within a bracket slot to produce torque within a bracket. Thirty Ormco Orthos Ti and 30 Orthos SS were compared to investigate the effect of torque on bracket material. Each bracket was mounted on a six-axis load cell that measured forces and moments in all directions. The archwire was rotated from an initial angle of 0 degree in 3 degrees increments to maximum angle of 51 degrees and then returned to the initial position. An overhead camera took images at each 3 degrees increment. The bracket images were post-processed using a digital image correlation technique to measure the relative deformation of each bracket slot. The maximum torque expressed at 51 degrees was 99.8 Nmm and 93.0 Nmm for Orthos Ti and Orthos SS, respectively. Total plastic deformation measured at 0 degrees post-torquing of the Orthos SS was 0.038 mm compared to 0.013 mm for Orthos Ti. The Orthos Ti brackets plastically deformed less than the Orthos SS brackets after torquing. The Orthos SS bracket plastic deformation was 2.8 times greater than that of Orthos Ti brackets. The Orthos Ti brackets expressed more torque than the stainless steel brackets but exhibited substantial variation.

摘要

正畸转矩表达是矩形弓丝在矩形托槽槽沟内轴向旋转的结果。本研究调查了托槽材料对转矩表达的影响。将测量旋转弓丝施加在每个托槽上的转矩以及每个托槽槽沟的相对变形。总共进行了60次测试,其中弓丝在托槽槽沟内旋转以在托槽内产生转矩。比较了30个奥美科Ortho Ti托槽和30个Ortho SS托槽,以研究转矩对托槽材料的影响。每个托槽安装在一个六轴测力传感器上,该传感器可测量各个方向的力和力矩。弓丝从初始角度0度开始,以3度的增量旋转至最大角度51度,然后返回初始位置。在每次3度增量时,由一台高架摄像机拍摄图像。使用数字图像相关技术对托槽图像进行后处理,以测量每个托槽槽沟的相对变形。在51度时,Ortho Ti托槽和Ortho SS托槽分别表达的最大转矩为99.8 Nmm和93.0 Nmm。在对Ortho SS托槽施加转矩后,在0度时测量的总塑性变形为0.038 mm,而Ortho Ti托槽为0.013 mm。在施加转矩后,Ortho Ti托槽的塑性变形小于Ortho SS托槽。Ortho SS托槽的塑性变形比Ortho Ti托槽大2.8倍。Ortho Ti托槽比不锈钢托槽表达的转矩更多,但存在显著差异。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验