This study examined the ability of tissue culture fibroblasts to attach and colonize on the surface of pure titanium dental implants following instrumentation of the implant surface with curettes of dissimilar composition. Pure titanium dental implants were scaled with a plastic, titanium-alloy, or stainless steel curette and then immersed in a cell suspension of 3T3 fibroblasts. Counts of attached cells were made at 24 and 72 hours; the implants were then processed for scanning electron microscopy (SEM). At 24 hours, only surfaces scaled with a stainless steel curette showed a significant reduction in number of attached cells relative to untreated control surfaces. At 72 hours, both stainless steel and titanium-alloy curette instrumented surfaces showed significantly fewer attached cells than untreated control surfaces, with the greatest reduction in cell attachment observed on the stainless steel curette instrumented surfaces. SEM observations showed that fibroblasts on stainless steel instrumented surfaces tended to show a somewhat rounded morphology and a relatively reduced degree of spreading: while fibroblasts on untreated control, plastic, or titanium-alloy instrumented surfaces showed a well-spread, polygonal morphology, more typical of fibroblasts in favorable culture conditions. To the extent that such observations of cell attachment and morphology are indicative of in vivo biocompatibility, these findings could have clinical implications for the proper maintenance of titanium dental implants.

摘要

本研究检测了在使用不同成分的刮匙对纯钛牙种植体表面进行器械处理后,组织培养成纤维细胞在其表面附着和定植的能力。用塑料刮匙、钛合金刮匙或不锈钢刮匙对纯钛牙种植体进行刮治,然后将其浸入3T3成纤维细胞的细胞悬液中。在24小时和72小时时对附着细胞进行计数;然后对种植体进行扫描电子显微镜(SEM)处理。在24小时时,相对于未处理的对照表面,仅用不锈钢刮匙刮治的表面附着细胞数量显著减少。在72小时时,用不锈钢和钛合金刮匙处理的表面附着细胞均明显少于未处理的对照表面,其中用不锈钢刮匙处理的表面细胞附着减少最为明显。SEM观察显示,在不锈钢处理的表面上,成纤维细胞往往呈现出某种程度的圆形形态且铺展程度相对降低;而在未处理的对照表面、塑料处理表面或钛合金处理表面上的成纤维细胞呈现出铺展良好的多边形形态,这在良好培养条件下的成纤维细胞中更为典型。就细胞附着和形态的这些观察结果可指示体内生物相容性而言,这些发现可能对钛牙种植体的正确维护具有临床意义。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验