Suppr超能文献

视网膜外观正常的患者出现异常多焦视网膜电图结果。

Abnormal multifocal ERG findings in patients with normal-appearing retinal anatomy.

作者信息

Talamini Christine L, Raza Ali S, Dale Elizabeth A, Greenstein Vivienne C, Odel Jeffrey G, Hood Donald C

机构信息

Department of Psychology, Columbia University, 406 Schermerhorn Hall, 1190 Amsterdam Avenue, New York, NY 10027, USA.

出版信息

Doc Ophthalmol. 2011 Dec;123(3):187-92. doi: 10.1007/s10633-011-9297-7. Epub 2011 Nov 2.

Abstract

To evaluate eyes with abnormal visual fields and multifocal electroretinograms (mfERGs) but normal-appearing frequency-domain optical coherence tomography (fdOCT) scans, the thicknesses of the outer retinal layers were measured. A total of 25 eyes from 17 patients, including 15 eyes previously tested (Dale et al. in Doc Ophthalmol 120(2):175-186, 2009) were examined. All patients were evaluated with standard automated perimetry (SAP) using the 24-2 and/or 10-2 program (Zeiss Meditec), mfERG with 103 hexagons (Veris, EDI), and fdOCT imaging (3DOCT-2000, Topcon) with scans of the macula. All patients had reliable visual fields showing macular defects and good quality mfERG and fdOCT results. The mfERG results were classified as abnormal based on decreased amplitudes and/or increased latencies corresponding to the abnormal visual field. Based on visual inspection, three experienced observers classified the fdOCT scans as normal or inconclusive, as opposed to clearly abnormal. Retinal layers of the fdOCT scans were manually segmented with the aid of a computer program and compared to mean thicknesses from 20 controls. The thicknesses of the outer segment plus retinal pigment epithelium, total receptor, and inner nuclear layers were measured. Quantitative analysis of fdOCT scans demonstrated thinning of the outer retina in some scans that was not readily apparent on visual inspection. One or more of the outer retinal layers was significantly thinner in 15 of the 25 eyes. The absence of significant thinning in the other 10 eyes represents instances in which functional loss measured by visual fields and mfERGs can precede clear structural changes on fdOCT.

摘要

为评估视野异常且多焦视网膜电图(mfERG)异常但频域光学相干断层扫描(fdOCT)扫描外观正常的眼睛,测量了视网膜外层的厚度。共检查了17例患者的25只眼睛,其中包括15只先前已检测过的眼睛(Dale等人,《眼科文献》120(2):175 - 186,2009年)。所有患者均使用24 - 2和/或10 - 2程序(蔡司医疗技术公司)进行标准自动视野计(SAP)检查、使用103个六边形的mfERG(Veris,EDI)检查以及使用黄斑扫描的fdOCT成像(3DOCT - 2000,拓普康)检查。所有患者的视野可靠,显示黄斑缺损,且mfERG和fdOCT结果质量良好。根据与异常视野相对应的振幅降低和/或潜伏期延长,将mfERG结果分类为异常。基于视觉检查,三名经验丰富的观察者将fdOCT扫描分类为正常或不确定,而非明显异常。在计算机程序的辅助下,对fdOCT扫描的视网膜层进行手动分割,并与20名对照者的平均厚度进行比较。测量了外段加视网膜色素上皮、总感受器和内核层的厚度。fdOCT扫描的定量分析表明,在一些扫描中视网膜外层变薄,而在视觉检查中并不容易看出。25只眼睛中有15只眼睛的一个或多个视网膜外层明显变薄。另外10只眼睛没有明显变薄,这代表了通过视野和mfERG测量的功能丧失可能先于fdOCT上明显的结构变化的情况。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/aadb/4456084/409c2894f828/nihms695350f1.jpg

相似文献

引用本文的文献

本文引用的文献

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验