Department of Chemistry, Faculty of Arts and Sciences, Istanbul Technical University, 34469 Maslak-Istanbul, Turkey.
Food Addit Contam Part A Chem Anal Control Expo Risk Assess. 2012;29(2):208-16. doi: 10.1080/19440049.2011.631193. Epub 2011 Nov 21.
A slurry sampling method is proposed for the determination of iron and zinc in baby food by flame atomic absorption spectrometry without sample digestion prior to analysis. The effect of slurry concentration (the ratio of solid sample to total slurry volume), different acids at various concentrations as diluent and the addition of dispersant on accuracy and precision were investigated. The samples were dried at 105 °C overnight and ground using an agate mortar. To obtain quantitative recoveries, 500 mg of sample was slurried in 20 ml of 0.05% Triton X-114 containing 0.1 M HNO(3), homogenised using a high-performance overhead disperser at 15,000 rpm for 5 min and directly aspirated into the flame. The accuracy of the method was tested by determination of analytes in various certified reference materials. The limits of detection of the method (N = 10; 3σ) for iron and zinc were 5.5 and 3.4 µg g(-1), respectively, using a very dilute slurry of baby food, which gave a very low background signal. Finally, the proposed method was applied to the determination of iron and zinc in different baby food samples obtained from markets in Turkey. The range of iron and zinc content for the samples were 33-76 and 15-73 µg g(-1), respectively.
提出了一种浆体取样法,用于火焰原子吸收光谱法测定婴儿食品中的铁和锌,无需在分析前对样品进行消化。考察了浆体浓度(固样与总浆体体积之比)、不同浓度的酸作为稀释剂以及分散剂的添加对准确性和精密度的影响。将样品在 105°C 下干燥过夜,然后用玛瑙研钵研磨。为了获得定量回收率,将 500mg 样品在含有 0.1M HNO(3)的 0.05% Triton X-114 中浆化 20ml,使用高性能顶置分散器以 15000rpm 均质化 5min,然后直接吸入火焰。通过测定各种认证参考物质中的分析物来测试该方法的准确性。使用非常稀的婴儿食品浆体,该方法的铁和锌检测限(N=10;3σ)分别为 5.5 和 3.4µg g(-1),这给出了非常低的背景信号。最后,将该方法应用于测定土耳其市场上不同婴儿食品样品中的铁和锌。这些样品的铁和锌含量范围分别为 33-76 和 15-73µg g(-1)。