Baksi B Güniz, Fidler Aleš
Department of Oral and Maxillofacial Radiology, Ege University, School of Dentistry, Izmir, Turkey.
Clin Oral Investig. 2012 Oct;16(5):1507-10. doi: 10.1007/s00784-011-0639-3. Epub 2011 Nov 29.
The aim of this study was to evaluate the effect of exposure time and image resolution on fractal dimension (FD) of periapical bone on images obtained using a storage phosphor plate (SPP) system.
Periapical images of premolar and molar teeth on both sides of ten dry human mandibles were obtained with Digora Optime (Soredex Corp., Helsinki, Finland) SPP system. The SPPs were exposed with three exposure times (0.05, 0.12, and 0.30 s) and scanned immediately after exposure with high and super resolutions. FD was calculated using public domain software (ImageJ with FracLac plug-in) on two non-overlapping region of interest (ROIs) on premolar and molar periapical bone areas of each radiograph using differential box-counting method. The ROIs on corresponding images were of the same size and position. FDs were compared using two-way ANOVA and Tukey-Kramer multiple comparison tests (p = 0.05).
Images obtained with super resolution scans gave significantly higher FD values compared to high-resolution scanning for all exposures (p < 0.0001). FD values were decreasing with increase in exposure time for both resolutions (p < 0.0001). The highest FD was found for images with super resolution and shortest exposure time, which exhibited the highest noise.
FD analysis seems not so robust method as it was believed previously. It shows significant changes with image resolution and exposure time.
Exposure time and scanning resolution of SPPs should be carefully chosen when evaluating the change in FD of alveolar bone for various bone disorders.
本研究旨在评估曝光时间和图像分辨率对使用存储磷光板(SPP)系统获取的根尖周骨图像分形维数(FD)的影响。
使用Digora Optime(芬兰赫尔辛基索雷德斯公司)SPP系统获取10具干燥人下颌骨两侧前磨牙和磨牙的根尖周图像。将SPP分别以三种曝光时间(0.05、0.12和0.30秒)进行曝光,并在曝光后立即以高分辨率和超分辨率进行扫描。使用公共领域软件(带有FracLac插件的ImageJ),采用差分盒计数法,在每张根尖片上前磨牙和磨牙根尖周骨区域的两个不重叠感兴趣区域(ROI)上计算FD。相应图像上的ROI大小和位置相同。使用双向方差分析和Tukey-Kramer多重比较检验(p = 0.05)比较FD值。
对于所有曝光,超分辨率扫描获得的图像的FD值显著高于高分辨率扫描(p < 0.0001)。两种分辨率下,FD值均随曝光时间增加而降低(p < 0.0001)。超分辨率且曝光时间最短的图像FD最高,但其噪声也最高。
FD分析似乎不像之前认为的那样是一种稳健的方法。它随图像分辨率和曝光时间有显著变化。
在评估各种骨疾病时牙槽骨FD的变化时,应谨慎选择SPP的曝光时间和扫描分辨率。