技术因素对不同牙科X光影像分形维数的影响。

The effects of technical factors on the fractal dimension in different dental radiographic images.

作者信息

Amuk Mehmet, Saribal Gamze Sirin, Ersu Nihal, Yilmaz Serkan

机构信息

Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Erciyes University, KayseriTurkiye.

出版信息

Eur Oral Res. 2023 May 4;57(2):68-74. doi: 10.26650/eor.2023984422.

Abstract

PURPOSE

The aim of this study was to assess the impact of exposure parameters and image formats on fractal dimension (FD) values in periapical, panoramic, and CBCT images.

MATERIALS AND METHODS

Seven dry male mandibles were selected, and a Gutta-Percha was used to identify identical regions of interest. A periapical radiograph was taken with 60 kVp/7 mA and exported in DICOM, JPEG, TIFF, and PNG formats. Nine periapical radiographs (60, 65, 70 kVp; 4, 5, 6 mA) were taken from seven dry human mandibles. Additionally, 12 panoramic radiographs (60, 70, 81, 90 kVp; 5, 8, 13 mA) and 10 CBCT images (with different scanning options and FOVs) were taken from each mandible. FDs were measured from a standard area.

RESULTS

The intra-class correlation coefficient demonstrated a high degree of agreement between observers. No significant difference was found between TIFF and PNG formats (p > 0.05). The highest FD mean was found in TIFF format, while the lowest FD mean was found in JPEG format (p<0.001). There was no significant difference between kVp and mA settings in periapical images. In panoramic images, a significant difference was found at 90 kVp (p = 0.001) and 13 mA (p<0.001), with lower FD values observed at these settings. There was no significant difference between FOV and resolution in CBCT images (p > 0.05).

CONCLUSION

The format of the image can influence FD. For periapical and panoramic radiographs, kVp and mA settings do not have a significant impact on FD. However, fractal analysis may not be an ideal method for evaluating three-dimensional images, such as those obtained with CBCT.

摘要

目的

本研究旨在评估曝光参数和图像格式对根尖片、全景片和锥形束CT(CBCT)图像分形维数(FD)值的影响。

材料与方法

选取七具干燥的男性下颌骨,使用牙胶尖确定相同的感兴趣区域。用60 kVp/7 mA拍摄根尖片,并以DICOM、JPEG、TIFF和PNG格式导出。从七具干燥的人类下颌骨上拍摄了九张根尖片(60、65、70 kVp;4、5、6 mA)。此外,从每具下颌骨上拍摄了12张全景片(60、70、81、90 kVp;5、8、13 mA)和10张CBCT图像(具有不同的扫描选项和视野)。从标准区域测量FD值。

结果

组内相关系数显示观察者之间具有高度一致性。TIFF和PNG格式之间未发现显著差异(p>0.05)。TIFF格式的FD平均值最高,而JPEG格式的FD平均值最低(p<0.001)。根尖片中kVp和mA设置之间没有显著差异。在全景片中,90 kVp(p = 0.立001)和13 mA(p<0.001)时存在显著差异,在这些设置下观察到较低的FD值。CBCT图像中视野和分辨率之间没有显著差异(p>0.05)。

结论

图像格式可影响FD。对于根尖片和全景片,kVp和mA设置对FD没有显著影响。然而,分形分析可能不是评估三维图像(如CBCT获得的图像)的理想方法。