Suppr超能文献

[正常门静脉系统的MRI:伪影。关于45例病例]

[MRI of the normal portal system: the artefacts. Apropos of 45 cases].

作者信息

Davy-Miallou C, Guinet C, Bellin M F, Curet P, Grellet J

机构信息

C.H.U. Pitié, Service de Radiologie Centrale, Paris.

出版信息

J Radiol. 1990 May;71(5):339-43.

PMID:2213696
Abstract

The protal system of 45 normal patients have been retrospectively studied on spin echo MRI sequences (interleaved cuts): multiple artifacts have been evaluated and 24% of them were visualized at the portal system level. Thus, partial volume effect responsible for almost 25% of the artifacts is not always easily seen on a single sequence. Respiratory and aortic artifacts can deteriorate the visualization of the vascular lumen but cannot be confused with a thrombosis. Well-known artifacts, as slice entry phenomenon and even echo rephasing, represent more than 60% of the artifacts: they are readily recognized when they are typical and indicate flowing blood. On the contrary, an other artifact, representing less than 5% of the total and seen at the level of the left portal vein, simulates a thrombus, on T2 weighed images. We conclude that the frequency and polymorphism of the artifacts are limiting factors of MRI value in the diagnosis of portal vein thrombosis.

摘要

对45例正常患者的门静脉系统进行了回顾性自旋回波MRI序列(交错切片)研究:评估了多种伪影,其中24%在门静脉系统层面可见。因此,造成近25%伪影的部分容积效应在单个序列上并不总是容易看到。呼吸和主动脉伪影会使血管腔的可视化变差,但不会与血栓混淆。众所周知的伪影,如层面进入现象甚至回波重聚,占伪影的60%以上:当它们典型时很容易识别,并提示血液流动。相反,另一种伪影占总数不到5%,在左门静脉层面可见,在T2加权图像上模拟血栓。我们得出结论,伪影的频率和多态性是MRI在门静脉血栓诊断中价值的限制因素。