Department of Surgery, Faculty of Medicine, University of Salamanca, Spain.
Med Oral Patol Oral Cir Bucal. 2012 May 1;17(3):e469-76. doi: 10.4317/medoral.17498.
OBJECTIVES: The purposes of this study are to validate the indicator of Oral Health Impact Profile for edentulous patients (OHIP-20sp) in the Spanish population and to analyze the factorial construct of the prosthetic well-being. STUDY DESIGN: [corrected] A total of twenty-one (n=21) edentulous patients wearing mandibular implant-overdentures on Locator® (LO) and twenty (n=20) with complete dentures (CD) were retrospectively evaluated in this study. All participants were recruited consecutively and were treated in the previous academic year 2009-2010 by professors of the University of Salamanca. Reliability analyses and validity tests were performed in order to evaluate the psychometric properties of OHIP-20sp employing two different total score methods (additional and simple count). A retrospective evaluation of the impact of the prosthetic treatment was captured with an evaluative instrument derived from OHIP-20, and named POST-OHIP-13. RESULTS: The reliability coefficient (Cronbach's alpha = 0.91) has shown a high internal consistency. Item-total correlations coefficients ranged from 0.46 and 0.81. Five factors, named as disability, functional comfort, psychosocial impact, pain-discomfort and functional limitations were identified as principal components of the construct, explaining almost 85% of the variance. The 48% of the sample felt at least one impact in an occasional or more frequently manner (generally food packing). The global transition judgment of the prosthetic treatment using the POST-OHIP-13 was significantly higher in group LO than in the CD group. CONCLUSIONS: OHIP-20 seems to be a reliable and valid indicator to measure oral impact and satisfaction in the Spanish edentulous population. The underlying construct is comprised by 5 factors named as disability, functional comfort, psychosocial impact, pain-discomfort and functional limitations.
目的:本研究旨在验证无牙颌患者口腔健康影响量表(OHIP-20sp)在西班牙人群中的有效性,并分析修复体幸福感的因子结构。
研究设计:本研究共回顾性评估了 21 名佩戴Locator®(LO)下颌种植覆盖义齿的无牙颌患者(n=21)和 20 名全口义齿患者(CD)(n=20)。所有参与者均连续招募,并于 2009-2010 学年由萨拉曼卡大学教授进行治疗。为了评估 OHIP-20sp 的心理测量特性,采用两种不同的总分方法(附加计数和简单计数)进行了可靠性分析和有效性测试。采用源自 OHIP-20 的评估工具对修复体治疗的影响进行回顾性评估,并将其命名为 POST-OHIP-13。
结果:可靠性系数(Cronbach's alpha = 0.91)显示出高度的内部一致性。项目总分相关系数范围为 0.46 至 0.81。确定了五个因素,分别命名为残疾、功能舒适度、心理社会影响、疼痛不适和功能限制,作为结构的主要成分,解释了近 85%的方差。48%的样本偶尔或更频繁地感到至少有一种影响(通常是食物包装)。使用 POST-OHIP-13 对修复体治疗的总体过渡判断,LO 组显著高于 CD 组。
结论:OHIP-20 似乎是一种可靠和有效的指标,可以衡量西班牙无牙颌人群的口腔影响和满意度。基础结构由 5 个因素组成,分别命名为残疾、功能舒适度、心理社会影响、疼痛不适和功能限制。
Med Oral Patol Oral Cir Bucal. 2012-5-1
Med Oral Patol Oral Cir Bucal. 2009-1-1
Community Dent Oral Epidemiol. 2008-2
Braz Oral Res. 2018-10-29
BMC Oral Health. 2014-8-4
J Oral Rehabil. 2009-6-7
Int Dent J. 2009-4
J Prosthodont. 2009-7
Med Oral Patol Oral Cir Bucal. 2009-1-1
Community Dent Oral Epidemiol. 2008-6
Gerodontology. 2006-3
J Public Health Dent. 2005
J Dent Res. 2004-12