Abstract

PURPOSE

To measure the stiffness of commonly used "stiff" guidewires in terms of their flexural modulus, an engineering parameter related to bending stiffness.

METHODS

Eleven different intact stiff guidewires were selected to undergo a 3-point bending test performed using a tensile testing machine. Testing was performed on 3 new and intact specimens of each guidewire at 10 locations along the wire's length, excluding the floppy tip. The flexural modulus (in gigapascals, GPa) was calculated from the results of the bending test.

RESULTS

The flexural modulus of the plain Amplatz wire was 9.5 GPa compared to 11.4 to 14.5 GPa for the "heavy duty" wires. Within the Amplatz family of guidewires, the flexural modulus was 17 GPa for the "stiff," 29.2 GPa for the "extra stiff," 60.3 GPa for the "super stiff," and 65.4 GPa for the "ultra stiff." The Backup Meier measured 139.6 GPa and the Lunderquist Extra Stiff 158.4 GPa.

CONCLUSION

The Instructions for Use of some endovascular devices specify a wire type selected from a range of undefined "stiffness" descriptors. These descriptors have little correlation with the measured flexural modulus. Two guidewires with the description "extra stiff" can have a 5-fold difference in flexural modulus. We recommend that guidewire catalogues and packaging include the flexural modulus and that device manufacturers amend their Instructions for Use accordingly.

摘要

目的

测量常用的“硬”导丝的弯曲模数,这是一个与弯曲刚度相关的工程参数。

方法

选择了 11 根完整的硬导丝进行三点弯曲测试,使用拉力试验机进行测试。对每根导丝的 3 个新的完整样本在远离软头的导丝长度上的 10 个位置进行测试。弯曲模数(以千兆帕斯卡,GPa 为单位)是从弯曲测试结果中计算得出的。

结果

普通 Amplatz 导丝的弯曲模数为 9.5GPa,而“重型”导丝的弯曲模数为 11.4 至 14.5GPa。在 Amplatz 系列导丝中,“硬”导丝的弯曲模数为 17GPa,“超硬”导丝为 29.2GPa,“特硬”导丝为 60.3GPa,“超特硬”导丝为 65.4GPa。Backup Meier 导丝的弯曲模数为 139.6GPa,Lunderquist Extra Stiff 导丝的弯曲模数为 158.4GPa。

结论

一些血管内设备的使用说明指定了从一系列未定义的“硬度”描述符中选择的导丝类型。这些描述符与测量的弯曲模数相关性很小。两种描述为“超硬”的导丝的弯曲模数可能相差 5 倍。我们建议导丝目录和包装应包括弯曲模数,并且设备制造商应相应地修改其使用说明。