Photoelastic comparison of single tooth implant-abutment bone of platform switching vs conventional implant designs.

作者信息

Rossi Fabiana, Zavanelli Adriana Cristina, Zavanelli Ricardo Alexandre

机构信息

Department of Prevention and Oral Rehabilitation, FO-UFG, Goiás, Brazil.

出版信息

J Contemp Dent Pract. 2011 Mar 1;12(2):124-30. doi: 10.5005/jp-journals-10024-1021.

Abstract

OBJECTIVES

The maintenance and stability of peri-implantar soft tissue seem to be related to the crestal bone around the implant platform and different implant designs connections might affect this phenomenon. The aim of this study was to evaluate by photoelastic analysis the stress distribution in the cervical and apical site of implant-abutment interface of conventional implant joints (external hex, internal hex and cone morse) and compare to the novel platform switching design.

MATERIALS AND METHODS

It was fabricated photoelastic models using five different implant-abutment connection, one set of external hex (Alvim Ti, Neodent, Curitiba, Brazil), one set of internal hex (Full Osseotite, Biomet 3i, Florida, USA), one cone morse set (Alvim CM, Neodent, Curitiba, Brazil), and two sets of internal hex plus platform switching concept (Alvim II Plus, Neodent, Curitiba, Brazil) (Certain Prevail, Biomet 3i, Florida, USA). These models were submitted to two compressive loads, axial from 20 kgf (load I) and another (load II), inclined 45° from 10 kgf. During the qualitative analysis, digital pictures were taken from a polariscope, for each load situation. For the quantitative analyses in both situations of load, the medium, minimum and maximum in MPa values of shear strain were determined in the cervical and apical site. The Kruskal-Wallis test was used to compare the results between the different systems and between cervical and apical site were compared using Mann-Whitney U test.

RESULTS

The results from qualitative analysis showed less concentration of strain in the cervical area to the internal hex plus platform switching (Certain Prevail), in both situation of load. The same results were get in the quantitative analysis, showing less stress concentrations around the implant Certain Prevail with internal hex plus the novel design (17.9 MPa to load I and 29.5 MPa to load II), however, without statistical significant difference between the systems.

CONCLUSION

The minor stress concentration strongly suggest the use of platform switching design as a manner to prevent bone loss around the implant-abutment platform.

CLINICAL SIGNIFICANCE

From the result of this study its possible to make clinical decision for implant system which provides implant components with platform switching characteristics.

摘要

目的

种植体周围软组织的维持和稳定性似乎与种植体平台周围的嵴顶骨有关,不同的种植体设计连接方式可能会影响这一现象。本研究的目的是通过光弹性分析评估传统种植体连接方式(外六角、内六角和莫氏锥度)的种植体-基台界面颈部和根尖部位的应力分布,并与新型平台转换设计进行比较。

材料与方法

使用五种不同的种植体-基台连接方式制作光弹性模型,一组外六角(Alvim Ti,Neodent,巴西库里蒂巴),一组内六角(Full Osseotite,Biomet 3i,美国佛罗里达),一组莫氏锥度(Alvim CM,Neodent,巴西库里蒂巴),以及两组内六角加平台转换概念(Alvim II Plus,Neodent,巴西库里蒂巴)(Certain Prevail,Biomet 3i,美国佛罗里达)。这些模型承受两种压缩载荷,轴向20千克力(载荷I)和另一种(载荷II),倾斜45°,10千克力。在定性分析过程中,针对每种载荷情况,从偏光镜拍摄数码照片。对于两种载荷情况下的定量分析,在颈部和根尖部位确定剪切应变的中值、最小值和最大值(单位为兆帕)。使用Kruskal-Wallis检验比较不同系统之间的结果,使用Mann-Whitney U检验比较颈部和根尖部位之间的结果。

结果

定性分析结果显示,在两种载荷情况下,内六角加平台转换(Certain Prevail)在颈部区域的应变集中程度较低。定量分析也得到了相同的结果,显示内六角加新型设计的Certain Prevail种植体周围的应力集中较小(载荷I时为17.9兆帕,载荷II时为29.5兆帕),然而,各系统之间无统计学显著差异。

结论

较小的应力集中强烈表明使用平台转换设计作为防止种植体-基台平台周围骨质流失的一种方式。

临床意义

根据本研究结果,可为提供具有平台转换特性的种植体部件的种植系统做出临床决策。