Carvalhal Cintia Iara Oda, Mello Jose Antonio Nunes de, Sobrinho Lourenco Correr, Correr Americo Bertolazzo, Sinhoreti Mario Alexandre Coelho
Department of Dental Materials and OdontologyUniversity of State of Amazonas, Amazonas, Brazil.
J Contemp Dent Pract. 2011 Jul 1;12(4):252-8. doi: 10.5005/jp-journals-10024-1043.
The aim of this study was to evaluate the influence of immersion period in two disinfectant solutions on dimensional change of four elastomeric impression materials.
Four representative materials of each class of elastomers: Xantopren (polydimethylsiloxane-PDS), Express (polyvinyl siloxane-PVS); Permlastic (polysulfide- PS) and Soft Impregum (polyether-EP) were mixed according to manufacturers' instructions and then inserted into a metal matrix prepared according to the specification of ISO 4823. The molds were removed from the matrix after 7 minutes and immersed in disinfectant solutions (sodium hypochlorite 0.5 and 2% glutaraldehyde) for 5, 10, 20, 30 and 60 minutes (n = 7), except the control group, which was not immersed. Once removed from solutions, the test samples were washed in water for 15 seconds, dried and measured three times, using a comparative optical microscope, with accuracy of 0.0005 mm. The analysis of variance with three criteria and Tukey's test with significance level of 5% showed that differences in linear dimensions of the materials analyzed were not statistically significant (p > 0.05) after soaking in sodium hypochlorite 0.5 and 2% glutaraldehyde, for the tested periods of time.
Combinations of molding material and disinfecting solution can be used in the dental clinic for infection control, without changing the dimensional molds, for immersion periods not longer than 20 minutes.
本研究旨在评估四种弹性印模材料在两种消毒溶液中的浸泡时间对尺寸变化的影响。
按照制造商说明混合每类弹性体的四种代表性材料:Xantopren(聚二甲基硅氧烷-PDS)、Express(聚乙烯基硅氧烷-PVS);Permlastic(聚硫橡胶-PS)和Soft Impregum(聚醚-EP),然后将其插入根据ISO 4823规范制备的金属模具中。7分钟后从模具中取出印模,并浸泡在消毒溶液(0.5%次氯酸钠和2%戊二醛)中5、10、20、30和60分钟(n = 7),对照组不进行浸泡。从溶液中取出后,测试样本在水中冲洗15秒,干燥并使用比较光学显微镜测量三次,精度为0.0005毫米。采用三因素方差分析和显著性水平为5%的Tukey检验表明,在测试时间段内,将材料浸泡在0.5%次氯酸钠和2%戊二醛中后,所分析材料的线性尺寸差异无统计学意义(p > 0.05)。
在牙科诊所中,对于不超过20分钟的浸泡时间,成型材料和消毒溶液的组合可用于感染控制,而不会改变尺寸模具。