Martin N, Martin M V, Jedynakiewicz N M
Department of Adult Dental Care, The University of Sheffield, Sheffield, United Kingdom.
Dent Mater. 2007 Jun;23(6):760-8. doi: 10.1016/j.dental.2007.01.004. Epub 2007 Mar 13.
This investigation examined the effect of several disinfectant systems upon the dimensional stability of a range of common dental impression materials. A new disinfection process based upon hypochlorous acid was one of those examined (Sterilox).
Test specimens of commercially available impression materials from the following categories were investigated: alginates, addition-cured silicones, condensation-cured silicones and polyether. Three disinfection regimes were tested: sodium hypochlorite 5.25%, Perform ID and Sterilox. A custom-built automatic laser micrometer was used to measure the dimensions of sample discs of the test materials before disinfection, immediately after and then following 24h storage. Analysis of variance was employed to identify statistically significant differences within groups and across groups.
All the disinfection routines tested resulted in acceptable levels of dimensional stability within the category of normal use of each impression material. All the materials tested can be disinfected with 10% Sterilox without undergoing unacceptable levels of dimensional change.
All the disinfection routines tested resulted in acceptable levels of dimensional stability within the category of normal use of each impression material.
本研究考察了几种消毒系统对一系列常见牙科印模材料尺寸稳定性的影响。基于次氯酸的一种新消毒工艺(Sterilox)是其中被考察的一种。
对以下类别的市售印模材料的测试样本进行了研究:藻酸盐类、加成型硅橡胶、缩合型硅橡胶和聚醚类。测试了三种消毒方案:5.25%次氯酸钠、Perform ID和Sterilox。使用定制的自动激光测微仪在消毒前、消毒后立即以及储存24小时后测量测试材料样本圆盘的尺寸。采用方差分析来确定组内和组间的统计学显著差异。
在每种印模材料的正常使用范围内,所有测试的消毒程序都产生了可接受的尺寸稳定性水平。所有测试材料都可以用10%的Sterilox进行消毒,而不会发生不可接受程度的尺寸变化。
在每种印模材料的正常使用范围内,所有测试的消毒程序都产生了可接受的尺寸稳定性水平。