头部 CT 自适应统计迭代重建:降低辐射剂量同时提高图像质量。

Cranial CT with adaptive statistical iterative reconstruction: improved image quality with concomitant radiation dose reduction.

机构信息

Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts 02114-9657, USA.

出版信息

AJNR Am J Neuroradiol. 2012 Apr;33(4):609-15. doi: 10.3174/ajnr.A2826. Epub 2011 Dec 29.

Abstract

BACKGROUND AND PURPOSE

To safeguard patient health, there is great interest in CT radiation-dose reduction. The purpose of this study was to evaluate the impact of an iterative-reconstruction algorithm, ASIR, on image-quality measures in reduced-dose head CT scans for adult patients.

MATERIALS AND METHODS

Using a 64-section scanner, we analyzed 100 reduced-dose adult head CT scans at 6 predefined levels of ASIR blended with FBP reconstruction. These scans were compared with 50 CT scans previously obtained at a higher routine dose without ASIR reconstruction. SNR and CNR were computed from Hounsfield unit measurements of normal GM and WM of brain parenchyma. A blinded qualitative analysis was performed in 10 lower-dose CT datasets compared with higher-dose ones without ASIR. Phantom data analysis was also performed.

RESULTS

Lower-dose scans without ASIR had significantly lower mean GM and WM SNR (P = .003) and similar GM-WM CNR values compared with higher routine-dose scans. However, at ASIR levels of 20%-40%, there was no statistically significant difference in SNR, and at ASIR levels of ≥60%, the SNR values of the reduced-dose scans were significantly higher (P < .01). CNR values were also significantly higher at ASIR levels of ≥40% (P < .01). Blinded qualitative review demonstrated significant improvements in perceived image noise, artifacts, and GM-WM differentiation at ASIR levels ≥60% (P < .01).

CONCLUSIONS

These results demonstrate that the use of ASIR in adult head CT scans reduces image noise and increases low-contrast resolution, while allowing lower radiation doses without affecting spatial resolution.

摘要

背景与目的

为了保障患者健康,人们对降低 CT 辐射剂量非常感兴趣。本研究旨在评估迭代重建算法 ASIR 对成人低剂量头部 CT 扫描的图像质量测量值的影响。

材料与方法

使用一台 64 排扫描仪,我们分析了 100 例经 6 种预设 ASIR 混合 FBP 重建水平的成人低剂量头部 CT 扫描,与 50 例之前未采用 ASIR 重建的常规高剂量 CT 扫描进行比较。从脑实质正常 GM 和 WM 的 Hounsfield 单位测量值计算 SNR 和 CNR。在与未采用 ASIR 的高剂量 CT 数据集比较的 10 例低剂量 CT 数据集中进行了盲法定性分析。还进行了体模数据分析。

结果

未采用 ASIR 的低剂量扫描与高常规剂量扫描相比,GM 和 WM 的平均 SNR 显著降低(P =.003),GM-WM CNR 值相似。然而,在 ASIR 水平为 20%-40%时,SNR 没有统计学上的显著差异,在 ASIR 水平≥60%时,低剂量扫描的 SNR 值显著升高(P<.01)。在 ASIR 水平≥40%时,CNR 值也显著升高(P<.01)。盲法定性评价表明,在 ASIR 水平≥60%时,图像噪声、伪影和 GM-WM 差异的感知质量显著改善(P<.01)。

结论

这些结果表明,在成人头部 CT 扫描中使用 ASIR 可降低图像噪声,提高低对比度分辨率,同时允许降低辐射剂量而不影响空间分辨率。

相似文献

1
Cranial CT with adaptive statistical iterative reconstruction: improved image quality with concomitant radiation dose reduction.
AJNR Am J Neuroradiol. 2012 Apr;33(4):609-15. doi: 10.3174/ajnr.A2826. Epub 2011 Dec 29.
3
Radiation dose reduction in soft tissue neck CT using adaptive statistical iterative reconstruction (ASIR).
Eur J Radiol. 2013 Dec;82(12):2222-6. doi: 10.1016/j.ejrad.2013.08.014. Epub 2013 Aug 23.
7
New scanning technique using Adaptive Statistical Iterative Reconstruction (ASIR) significantly reduced the radiation dose of cardiac CT.
J Med Imaging Radiat Oncol. 2013 Jun;57(3):292-6. doi: 10.1111/1754-9485.12019. Epub 2013 Jan 7.
8
The Application of a New Model-Based Iterative Reconstruction in Low-Dose Upper Abdominal CT.
Acad Radiol. 2019 Oct;26(10):e275-e283. doi: 10.1016/j.acra.2018.11.020. Epub 2019 Jan 17.
9
Iterative Reconstruction for Head CT: Effects on Radiation Dose and Image Quality.
Can J Neurol Sci. 2014 Sep;41(5):620-5. doi: 10.1017/cjn.2014.11.

引用本文的文献

1
Comparison of ADMIRE, SAFIRE, and Filtered Back Projection in Standard and Low-Dose Non-Enhanced Head CT.
Diagnostics (Basel). 2025 Jun 17;15(12):1541. doi: 10.3390/diagnostics15121541.
2
Development and validation of the effective CNR analysis method for evaluating the contrast resolution of CT images.
Phys Eng Sci Med. 2024 Jun;47(2):717-727. doi: 10.1007/s13246-024-01400-5. Epub 2024 Mar 7.
4
Computed Tomography of the Head : A Systematic Review on Acquisition and Reconstruction Techniques to Reduce Radiation Dose.
Clin Neuroradiol. 2023 Sep;33(3):591-610. doi: 10.1007/s00062-023-01271-5. Epub 2023 Mar 2.
7
Brain Segmentation From Computed Tomography of Healthy Aging and Geriatric Concussion at Variable Spatial Resolutions.
Front Neuroinform. 2019 Mar 18;13:9. doi: 10.3389/fninf.2019.00009. eCollection 2019.
9
Low-Dose CCT to Exclude Contraindications to Lumbar Puncture : Benefits and Limitations.
Clin Neuroradiol. 2019 Mar;29(1):117-123. doi: 10.1007/s00062-017-0628-2. Epub 2017 Sep 30.
10
Head CT: Image quality improvement with ASIR-V using a reduced radiation dose protocol for children.
Eur Radiol. 2017 Sep;27(9):3609-3617. doi: 10.1007/s00330-017-4733-z. Epub 2017 Jan 23.

本文引用的文献

1
Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT: a pilot study.
Radiology. 2011 May;259(2):565-73. doi: 10.1148/radiol.11101450. Epub 2011 Mar 8.
2
Reducing abdominal CT radiation dose with adaptive statistical iterative reconstruction technique.
Invest Radiol. 2010 Apr;45(4):202-10. doi: 10.1097/RLI.ob013e3181dzfeec.
6
Is iterative reconstruction ready for MDCT?
J Am Coll Radiol. 2009 Apr;6(4):274-6. doi: 10.1016/j.jacr.2008.12.014.
7
Strategies for reducing radiation dose in CT.
Radiol Clin North Am. 2009 Jan;47(1):27-40. doi: 10.1016/j.rcl.2008.10.006.
8
CT technology overview: 64-slice and beyond.
Radiol Clin North Am. 2009 Jan;47(1):1-11. doi: 10.1016/j.rcl.2008.10.004.
9
The radiologist's conundrum: benefits and costs of increasing CT capacity and utilization.
Eur Radiol. 2009 Jan;19(1):9-11; discussion 12. doi: 10.1007/s00330-008-1159-7. Epub 2008 Sep 3.
10
An outlook on x-ray CT research and development.
Med Phys. 2008 Mar;35(3):1051-64. doi: 10.1118/1.2836950.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验