用于长石质瓷表面处理的最佳酸化磷酸氟凝胶蚀刻时间:对树脂复合材料的剪切粘结强度的影响

Optimal acidulated phosphate fluoride gel etching time for surface treatment of feldspathic porcelain: on shear bond strength to resin composite.

作者信息

Kukiattrakoon Boonlert, Thammasitboon Kewalin

机构信息

Prince of Songkla University, Faculty of Dentistry Dental Materials Research Unit, Hat Yai, Songkhla, Thailand.

出版信息

Eur J Dent. 2012 Jan;6(1):63-9.

Abstract

OBJECTIVES

This in vitro study evaluated the shear bond strength (SBS) of resin composite to feldspathic porcelain after acidulated phosphate fluoride (APF) gel treatment over different periods of time.

METHODS

One hundred and fifty-six feldspathic specimens were divided into 12 groups. Group C received no treatment (control group). Groups APF1 through APF10, ten experimental groups, were treated with 1.23% APF gel. Each group obtained 1 to 10 minutes of etching time in 1 minute increments, respectively. Group HF2 was treated with 9.6% hydrofluoric acid (HF) for 2 minutes. All specimens were then bonded to a resin composite cylinder using Adper Scotchbond Multi-purpose (3M ESPE) after silane (Monobond-S, Ivoclar Vivadent AG) application. Specimens were stored at 37ºC for 24 hours before the SBS was performed and were recorded in MPa at fracture. Data were analyzed using one-way ANOVA and Tukey's test (α=.05).

RESULTS

HF etching yielded the highest SBS (18.0 ± 1.5 MPa), which was not significantly different from APF gel etching for 6 to 10 minutes (16.0 ± 2.1 to 17.2 ± 1.6 MPa) (P>.05).

CONCLUSIONS

APF gel etching for 6 minutes might be used as an alternative etchant to HF acid for bonding resin composite to silanized feldspathic porcelain.

摘要

目的

本体外研究评估了在不同时间段经酸化磷酸氟(APF)凝胶处理后树脂复合材料与长石质瓷之间的剪切粘结强度(SBS)。

方法

156个长石质标本被分为12组。C组未接受处理(对照组)。APF1至APF10组为十个实验组,用1.23%的APF凝胶进行处理。每组分别获得1至10分钟的蚀刻时间,以1分钟为增量。HF2组用9.6%的氢氟酸(HF)处理2分钟。然后,在应用硅烷(Monobond - S,义获嘉伟瓦登特股份公司)后,使用Adper Scotchbond多功能粘结剂(3M ESPE)将所有标本粘结到树脂复合材料圆柱体上。在进行SBS测试前,标本在37℃下储存24小时,并记录断裂时的兆帕数。数据采用单因素方差分析和Tukey检验(α = 0.05)进行分析。

结果

HF蚀刻产生的SBS最高(18.0±1.5兆帕),与APF凝胶蚀刻6至10分钟(16.0±2.1至17.2±1.6兆帕)相比无显著差异(P>0.05)。

结论

APF凝胶蚀刻6分钟可作为一种替代HF酸的蚀刻剂,用于将树脂复合材料粘结到硅烷化的长石质瓷上。