Suppr超能文献

圆锥外节尖端在视网膜前膜手术中作为预后因素的意义。

The significance of cone outer segment tips as a prognostic factor in epiretinal membrane surgery.

机构信息

Department of Ophthalmology, Kobe City Medical Center General Hospital, Kobe, Japan.

出版信息

Am J Ophthalmol. 2012 Apr;153(4):698-704, 704.e1. doi: 10.1016/j.ajo.2011.09.011. Epub 2012 Jan 14.

Abstract

PURPOSE

To evaluate the prognostic value of the cone outer segment tips (COST) and other features using spectral-domain optical coherence tomography (SD-OCT) in patients undergoing epiretinal membrane (ERM) surgery.

DESIGN

Retrospective observational case series.

METHODS

Fifty eyes of 49 patients that underwent vitrectomy for idiopathic ERM were studied. Best-corrected visual acuity (BCVA) and SD-OCT images were examined preoperatively and at 1 and 6 months postoperatively. The SD-OCT features evaluated included central foveal thickness (CFT) and the status and defect diameter of the external limiting membrane (ELM), the photoreceptor inner/outer segment (IS/OS) junction, and the COST line. The associations between SD-OCT parameters and BCVA were analyzed.

RESULTS

There was no ELM disruption found, and thus the eyes were categorized into 3 groups: Group A, with a continuous IS/OS and COST line; Group B, with a continuous IS/OS but disrupted COST line; and Group C, with a disrupted IS/OS and COST line. At 6 months, Group A showed a significantly better BCVA than Group B (P<.005), and poorer BCVA was noted in Group C (P=.034). Defect diameters of IS/OS and COST line were also significantly correlated with BCVA postoperatively. The BCVA at 6 months was better in order of Group A, B, and C as assigned at baseline (P<.05) or 1 month (P<.001). There was no significant correlation between CFT and BCVA.

CONCLUSIONS

The status of the COST line, in conjunction with the IS/OS junction, is a useful prognostic factor after ERM surgery.

摘要

目的

评估在接受视网膜前膜(ERM)手术的患者中,使用频域光相干断层扫描(SD-OCT)的圆锥外节尖端(COST)和其他特征的预后价值。

设计

回顾性观察性病例系列。

方法

对 49 例 50 只眼进行了玻璃体切除术治疗特发性 ERM。在术前和术后 1 个月和 6 个月检查最佳矫正视力(BCVA)和 SD-OCT 图像。评估的 SD-OCT 特征包括中央黄斑厚度(CFT)和外节限膜(ELM)的状态和缺损直径、光感受器内/外节(IS/OS)交界处和 COST 线。分析 SD-OCT 参数与 BCVA 之间的关系。

结果

未发现 ELM 中断,因此将眼分为 3 组:A 组,IS/OS 和 COST 线连续;B 组,IS/OS 连续但 COST 线中断;C 组,IS/OS 和 COST 线中断。6 个月时,A 组的 BCVA 明显优于 B 组(P<.005),C 组的 BCVA 较差(P=.034)。IS/OS 和 COST 线的缺损直径与术后 BCVA 也呈显著相关。根据基线(P<.05)或 1 个月(P<.001)时的分组,6 个月时的 BCVA 按 A、B 和 C 组的顺序更好。CFT 与 BCVA 无显著相关性。

结论

COST 线的状态与 IS/OS 交界处结合在一起,是 ERM 手术后有用的预后因素。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验