Suppr超能文献

7T 动物磁共振扫描仪上前列腺癌异种移植模型的弥散加权成像:ADC 值与病理发现的比较。

Diffusion-weighted imaging of a prostate cancer xenograft model seen on a 7 Tesla animal MR scanner: comparison of ADC values and pathologic findings.

机构信息

Department of Radiology, Yonsei University College of Medicine, Severance Hospital, Seoul 120-752, Korea.

出版信息

Korean J Radiol. 2012 Jan-Feb;13(1):82-9. doi: 10.3348/kjr.2012.13.1.82. Epub 2011 Dec 23.

Abstract

OBJECTIVE

To assess the relationship between apparent diffusion coefficient (ADC) values on diffusion-weighted magnetic resonance (MR) imaging and pathologic measures of a tumor using a prostate cancer xenograft model.

MATERIALS AND METHODS

Eighteen athymic nude mice with 36 PC-3-induced tumors were sacrificed to obtain specimens immediately after MR imaging in order to compare the findings on MR images with those seen on pathological specimens. Using a high-field small-animal MR scanner, T1- and T2-weighted imaging and DW MR imaging was performed. Tumors were then processed for Hematoxylin and Eosin staining to evaluate tumor cellularity, intratumoral necrosis and immunostaining using antibodies directed against CD31 and vascular endothelial growth factor (VEGF) to determine the levels of microvessel density (MVD). Mean ADC values that were measured on the solid portion within each tumor were compared with tumor volume, cellularity, degree of necrosis, VEGF expression, and MVD in the corresponding section of the pathological specimen.

RESULTS

Mean ADC values of the solid portion within the PC-3-induced high-grade tumors were significantly correlated with the degree of intratumoral necrosis (r = 0.63, p < 0.0001) and MVD (r = -0.44, p = 0.008) on pathologic slides. The ADC values were not significantly correlated with tumor cellularity, VEGF expression, or tumor volume in high-grade prostate cancer tissues.

CONCLUSION

In the xenografted prostate cancer model, the ADC values of the solid portion of the tumors are significantly correlated with tumor necrosis and MVD of the pathologic specimens. The ADC values may be utilized as surrogate markers for the noninvasive assessment of tumor necrosis and MVD in high-grade prostate cancer.

摘要

目的

利用前列腺癌异种移植模型评估磁共振扩散加权成像(DWI)表观扩散系数(ADC)值与肿瘤病理指标之间的关系。

材料与方法

对 36 个 PC-3 诱导的肿瘤进行 18 只无胸腺裸鼠实验,在 MR 成像后立即处死动物以获得标本,将 MR 图像与病理标本进行对比。使用高场小动物磁共振扫描仪进行 T1-、T2-加权成像和 DWI 成像。对肿瘤进行苏木精和伊红染色以评估肿瘤细胞密度、肿瘤内坏死和免疫组化染色,使用针对 CD31 和血管内皮生长因子(VEGF)的抗体来确定微血管密度(MVD)水平。对每个肿瘤实性部分测量的平均 ADC 值与肿瘤体积、细胞密度、坏死程度、VEGF 表达以及病理切片上相应区域的 MVD 进行比较。

结果

PC-3 诱导的高级别肿瘤实性部分的平均 ADC 值与肿瘤内坏死程度(r = 0.63,p < 0.0001)和病理切片上的 MVD(r = -0.44,p = 0.008)呈显著相关性。ADC 值与高级别前列腺癌组织中的肿瘤细胞密度、VEGF 表达或肿瘤体积无显著相关性。

结论

在异种移植的前列腺癌模型中,肿瘤实性部分的 ADC 值与肿瘤坏死和病理标本的 MVD 显著相关。ADC 值可作为评估高级别前列腺癌肿瘤坏死和 MVD 的非侵入性替代标志物。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/29f8/3253407/c7127c19fa0e/kjr-13-82-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验