Department of Radiology, College of Medicine, Chung-Ang University, Seoul, South Korea.
J Digit Imaging. 2012 Aug;25(4):486-91. doi: 10.1007/s10278-012-9458-6.
There is a growing interest in three-dimensional computed tomography (3D-CT) as a research tool for the study of bone, joint anatomy, and kinematics. However, when CT data are processed and handled manually using image processing programs to yield 3D image and coordinate value, systematic and random errors should be validated. We evaluated the accuracy and reliability of length measurement on CT with OsiriX software. 3D-CT scans were made of 14 frozen pig knees with five transosseous holes in the metaphyseal portion of femur. The lengths between tunnel orifices were measured using Mitutoyo Digimatic digital calipers to establish the gold standard, and with the OsiriX program in 3D multi-planar reformatting mode for comparison. All measurements were recorded by a principal (replicate 1, trial 1) and a secondary observer (replicate 2, trial 1) and were repeated once by each observer (trial 2). The mean differences between OsiriX and real measurements were less than 0.1 mm in both replicates, and maximum differences were less than 0.3 mm. There were no significant differences between the replicates and real measurements (p=0.544 and 0.622 for replicates 1 and 2, respectively). The intraclass correlation coefficients (ICC) were very high between trials and between replicates (ICC=0.998 and 0.999, respectively). For kinematic analysis of the knees, length measurements on 3D-CT using OsiriX program can be used as alternatives to real measurements with less than 0.3-mm accuracy and very high reliability.
人们对三维计算机断层扫描(3D-CT)作为研究骨骼、关节解剖结构和运动学的研究工具越来越感兴趣。然而,当使用图像处理程序手动处理 CT 数据以生成 3D 图像和坐标值时,应验证系统和随机误差。我们评估了 OsiriX 软件在 CT 上进行长度测量的准确性和可靠性。对 14 个冷冻猪膝关节进行了 3D-CT 扫描,在股骨干骺端有 5 个经骨隧道。使用 Mitutoyo Digimatic 数字卡尺测量隧道开口之间的长度,以建立金标准,并在 3D 多平面重建模式下使用 OsiriX 程序进行比较。所有测量均由主要观察者(重复 1,试验 1)和次要观察者(重复 2,试验 1)记录,并由每位观察者重复一次(试验 2)。在两个重复中,OsiriX 和真实测量之间的平均差异小于 0.1 毫米,最大差异小于 0.3 毫米。在重复和真实测量之间没有显著差异(分别为 p=0.544 和 0.622)。试验之间和重复之间的组内相关系数(ICC)非常高(ICC=0.998 和 0.999)。对于膝关节的运动学分析,使用 OsiriX 程序在 3D-CT 上进行的长度测量可以作为真实测量的替代方法,其准确性小于 0.3 毫米,可靠性非常高。