Department of Analytical Chemistry, Faculty of Chemistry, University Complutense of Madrid, Madrid, Spain.
Anal Bioanal Chem. 2012 May;403(4):939-46. doi: 10.1007/s00216-012-5753-9.
In this paper, an electrochemical magneto-immunosensor for the detection of human growth hormone (hGH) is described for the first time. The immunosensor involves the use of tosyl-activated magnetic microparticles (TsMBs) to covalently immobilize a monoclonal mAbhHG antibody. A sandwich-type immunoassay with a secondary pAbhGH antibody and anti-IgG labelled with alkaline phosphatase (anti-IgG-AP) was employed. TsMBs–mAbhGH–hGH–pAbhGH–anti-IgG-AP conjugates were deposited onto the surface of a screen-printed gold electrode using a small neodymium magnet, and electrochemical detection was performed by square-wave voltammetry upon the addition of 4-aminophenyl phosphate as the AP substrate. All the variables involved in the preparation of immunoconjugates and in the immunoassay protocol were optimized. A calibration curve for hGH was constructed with a linear range between 0.01 and 100 ng/mL (r = 0.998) and a limit of detection of 0.005 ng/mL. This value is nearly three orders of magnitude lower than that obtained using surface plasmon resonance (Treviño et al., Talanta 78:1011-1016, 2009). Furthermore, good repeatability, with RSD = 3% (n = 10) at the 1-ng/mL hGH level, was obtained. Cross-reactivity studies with other hormones demonstrated good selectivity. The magneto-immunosensor was applied to the analysis of human serum spiked with hGH at the 4- and 0.1-ng/mL levels. Mean recoveries of 96 ± 6% and 99 ± 2%, respectively, were obtained.
本文首次报道了一种用于检测人生长激素(hGH)的电化学磁免疫传感器。该免疫传感器涉及使用甲苯磺酰活化磁性微球(TsMBs)将单克隆 mAbhGH 抗体共价固定。采用夹心型免疫分析,使用二次 pAbhGH 抗体和碱性磷酸酶标记的抗 IgG(anti-IgG-AP)。TsMBs-mAbhGH-hGH-pAbhGH-anti-IgG-AP 缀合物使用小型钕磁铁沉积在丝网印刷金电极表面上,并通过添加 4-氨基苯磷酸盐作为 AP 底物进行方波伏安法电化学检测。优化了制备免疫缀合物和免疫分析方案中涉及的所有变量。构建了 hGH 的校准曲线,线性范围为 0.01-100ng/mL(r=0.998),检测限为 0.005ng/mL。这个值比使用表面等离子体共振(Treviño 等人,Talanta 78:1011-1016,2009)获得的检测限低近三个数量级。此外,在 1ng/mL hGH 水平下,获得了 3%(n=10)的良好重复性。与其他激素的交叉反应研究显示出良好的选择性。磁免疫传感器应用于分析人血清中添加 hGH 的 4ng/mL 和 0.1ng/mL 水平。分别获得 96±6%和 99±2%的平均回收率。