Suppr超能文献

磁免疫分析法检测和定量测定人生长激素。

Magneto-Immunoassay for the Detection and Quantification of Human Growth Hormone.

机构信息

Department of Immunology, State Research Institute Centre for Innovative Medicine, LT-08406 Vilnius, Lithuania.

Nanotechnas-Center of Nanotechnology and Materials Science, Faculty of Chemistry and Geosciences, Institute of Chemistry, Vilnius University, LT-03225 Vilnius, Lithuania.

出版信息

Biosensors (Basel). 2022 Jan 25;12(2):65. doi: 10.3390/bios12020065.

Abstract

Physiological and endocrine maintenance of a normal human growth hormone (hGH) concentration is crucial for growth, development, and a number of essential biological processes. In this study, we describe the preparation and characterization of magnetic nanoparticles coated with a gold shell (MNPs-Au). The optimal surface concentration of monoclonal anti-hGH antibodies (m-anti-hGH) on magnetic nanoparticles, as well as conditions that decrease non-specific interactions during the magneto-immunoassay, were elaborated. After the selective recognition, separation, and pre-concentration of hGH by MNPs-Au/m-anti-hGH and the hGH interaction with specific polyclonal biotin-labeled antibodies (p-anti-hHG-B) and streptavidin modified horseradish peroxidase (S-HRP), the MNPs-Au/m-anti-hGH/hGH/p-anti-hGH-B/S-HRP immunoconjugate was formed. The concentration of hGH was determined after the addition of 3,3',5,5'-tetramethylbenzidine and hydrogen peroxide substrate solution for HRP; the absorbance at 450 nm was registered after the addition of STOP solution. The developed sandwich-type colorimetric magneto-immunoassay is characterized by a clinically relevant linear range (from 0.1 to 5.0 nmol L, 0.9831), low limit of detection (0.082 nmol L), and negligible non-specific binding of other antibodies or S-HRP. The obtained results demonstrate the applicability of the developed magneto-immunoassay for the concentration and determination of hGH in the serum. Additionally, important technical solutions for the development of the sandwich-type colorimetric magneto-immunoassay are discussed.

摘要

维持人体正常生长激素 (hGH) 浓度的生理和内分泌功能对于生长、发育和许多重要的生物过程至关重要。在本研究中,我们描述了金壳包裹的磁性纳米粒子 (MNPs-Au) 的制备和表征。优化了磁性纳米粒子上单克隆抗 hGH 抗体 (m-anti-hGH) 的最佳表面浓度,以及降低磁免疫分析中非特异性相互作用的条件。通过 MNPs-Au/m-anti-hGH 选择性识别、分离和预浓缩 hGH,以及 hGH 与特异性多克隆生物素标记抗体 (p-anti-hHG-B) 和辣根过氧化物酶修饰链霉亲和素 (S-HRP) 的相互作用,形成 MNPs-Au/m-anti-hGH/hGH/p-anti-hGH-B/S-HRP 免疫复合物。加入 3,3',5,5'-四甲基联苯胺和辣根过氧化物酶底物溶液后,确定 hGH 的浓度;加入 STOP 溶液后,在 450nm 处记录吸光度。开发的三明治型比色磁免疫分析具有临床相关的线性范围(从 0.1 到 5.0nmol L, 0.9831)、低检测限(0.082nmol L)和其他抗体或 S-HRP 的可忽略的非特异性结合。获得的结果表明,所开发的磁免疫分析可用于血清中 hGH 的浓度和测定。此外,还讨论了开发三明治型比色磁免疫分析的重要技术解决方案。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/251a/8869458/226e079d750d/biosensors-12-00065-g001.jpg