近视 LASIK 术后 24 小时及 1 年上皮厚度变化的三维显示:Artemis 超高频数字超声。

Change in epithelial thickness profile 24 hours and longitudinally for 1 year after myopic LASIK: three-dimensional display with Artemis very high-frequency digital ultrasound.

机构信息

London Vision Clinic, United Kingdom.

出版信息

J Refract Surg. 2012 Mar;28(3):195-201. doi: 10.3928/1081597X-20120127-02. Epub 2012 Feb 1.

Abstract

PURPOSE

To longitudinally follow epithelial thickness profile changes after myopic LASIK for 1 year to determine when and how epithelial changes occur and when epithelial stability is reached.

METHODS

Epithelial thickness was measured with Artemis very high-frequency digital ultrasound (ArcScan Inc) across the central 10-mm corneal diameter in 11 eyes before and 1 day, and 1, 3, 6, and 12 months after myopic femtosecond LASIK. For each consecutive pair of time points, maps of the mean change in epithelial thickness and paired t test P value were plotted.

RESULTS

Mean preoperative spherical equivalent refraction was -3.34 ± 1.51 diopters (D) (range: -1.50 to -5.13 D). Overnight, there was a central 5-mm zone of epithelial thickening (0.5 to 1.5 μm, P<.05) surrounded by epithelial thinning (4 to 6 μm, P<.05) extending to the 8-mm zone. Between 1 day and 1 month, the epithelium thickened within the 7-mm zone by up to 5 μm (P<.05) in a lenticular pattern with greater thickening centrally and progressively less thickening centrifugally. Between 1 and 3 months, the epithelium continued to thicken in the central 7-mm zone by approximately 1 μm (P<.05). No change in epithelial thickness occurred after 3 months (P>.05).

CONCLUSIONS

A lenticular change occurred in the epithelial thickness profile, with more thickening centrally than paracentrally; 22% of the total increase in central thickness occurred overnight, 58% between 1 day and 1 month, and 20% between 1 and 3 months, with stability between 3 and 12 months. The lenticular epithelial changes contribute to the observed myopic shift after myopic LASIK during the first 3 months.

摘要

目的

通过对近视 LASIK 术后 1 年的上皮厚度进行纵向随访,以确定上皮变化发生的时间和方式,以及何时达到上皮稳定。

方法

使用 Artemis 超高频率数字超声仪(ArcScan Inc),在 11 只眼中测量角膜中央 10mm 直径范围内的上皮厚度,分别在术前、术后 1 天、1、3、6 和 12 个月时进行测量。对于每一对连续的时间点,绘制上皮厚度平均变化图和配对 t 检验 P 值。

结果

平均术前等效球镜屈光度为-3.34±1.51 屈光度(D)(范围:-1.50 至-5.13 D)。术后当晚,中央 5mm 区域上皮增厚(0.5 至 1.5μm,P<.05),周围上皮变薄(4 至 6μm,P<.05),延伸至 8mm 区域。在 1 天至 1 个月之间,上皮在 7mm 区域内增厚了 5μm(P<.05),呈透镜状,中央增厚更多,离心方向逐渐减少。在 1 至 3 个月之间,中央 7mm 区域的上皮继续增厚约 1μm(P<.05)。3 个月后,上皮厚度无变化(P>.05)。

结论

上皮厚度轮廓呈透镜状变化,中央比旁中央增厚更多;中央厚度总增加的 22%发生在术后当晚,58%发生在术后 1 天至 1 个月之间,20%发生在术后 1 至 3 个月之间,术后 3 至 12 个月之间稳定。在近视 LASIK 术后的前 3 个月,这种透镜状的上皮变化导致了观察到的近视漂移。