应用 200kHz 飞秒激光行 LASIK 术中角膜瓣厚度的可预测性。

Predictability of corneal flap thickness in laser in situ keratomileusis using a 200 kHz femtosecond laser.

机构信息

Wellington Eye Clinic and UPMC Beacon Hospital, School of Medicine and Medical Science, University College Dublin, Dublin, Ireland.

出版信息

J Cataract Refract Surg. 2013 Mar;39(3):378-85. doi: 10.1016/j.jcrs.2012.10.041. Epub 2013 Jan 23.

Abstract

PURPOSE

To compare the intended versus the resultant thickness of laser in situ keratomileusis (LASIK) flaps created with a new femtosecond laser and to report the 3-month postoperative refractive outcomes.

SETTING

Wellington Eye Clinic, Dublin, Ireland.

DESIGN

Retrospective consecutive case series.

METHODS

A consecutive series of eyes having LASIK flaps created using a Wavelight FS200 femtosecond laser were included in this analysis. Eyes with preoperative spherical equivalent (SE) myopic refractive errors up to -12.00 diopters (D), hyperopic refractive errors up to +5.50 D, and astigmatism up to 6.00 D received primary LASIK. Outcomes included postoperative flap thickness and 3-month postoperative refraction.

RESULTS

Outcomes in 431 eyes of 258 patients having LASIK with femtosecond flap creation were assessed. With an intended flap thickness of 120 μm, the mean post-LASIK flap thickness was 120.23 μm ± 13.94 (SD). In 349 of 813 eyes, EX500 optical pachymetry measurements were compared with Scheimpflug pachymetry readings. The mean corneal thickness was 553.52 ± 29.81 μm with optical pachymetry and 553.39 ± 29.12 μm with the Pentacam rotating Scheimpflug camera. In 162 eyes, the flap thickness was measured with optical coherence tomography; the mean was 121.94 ± 10.52 μm. Achieved flap dimensions were as intended.

CONCLUSIONS

This study provides evidence of the predictability and lower variability of LASIK flaps created using the femtosecond laser. Consecutive patients having LASIK had good, predictable, and stable outcomes at the 3-month mark.

摘要

目的

比较使用新的飞秒激光制作的 LASIK 瓣的预期厚度与实际厚度,并报告术后 3 个月的屈光结果。

地点

爱尔兰都柏林的惠灵顿眼科诊所。

设计

回顾性连续病例系列。

方法

本分析纳入了使用 Wavelight FS200 飞秒激光制作 LASIK 瓣的连续系列眼。术前等效球镜(SE)近视屈光度达-12.00 屈光度(D)、远视屈光度达+5.50 D、散光达 6.00 D 的患者接受初次 LASIK。结果包括术后瓣厚度和术后 3 个月的屈光。

结果

评估了 258 例患者的 431 只眼行飞秒瓣 LASIK 的结果。预期瓣厚度为 120 μm 时,LASIK 后瓣平均厚度为 120.23 μm±13.94(SD)。在 813 只眼中的 349 只眼中,EX500 光学测厚仪测量值与 Scheimpflug 测厚读数进行了比较。光学测厚的平均角膜厚度为 553.52±29.81 μm,Pentacam 旋转 Scheimpflug 相机的平均角膜厚度为 553.39±29.12 μm。在 162 只眼中,用光学相干断层扫描测量瓣厚度,平均值为 121.94±10.52 μm。达到的瓣尺寸与预期一致。

结论

本研究为使用飞秒激光制作的 LASIK 瓣的可预测性和较低的变异性提供了证据。连续患者在术后 3 个月有良好、可预测和稳定的结果。