Corneal Epithelium Asymmetry in Children With Atopy: The Effect of Hand Dominance.

作者信息

Loureiro Tomás, Rodrigues-Barros Sandra, Carreira Ana Rita, Gouveia-Moraes Filipe, Carreira Pedro, Vide Escada Ana, Campos Paul, Machado Inês, Campos Nuno, Archer Timothy J, Reinstein Dan Z, Ambrósio Renato

机构信息

Ophthalmology Department, Hospital Garcia de Orta, Almada, Portugal.

London Vision Clinic, London, UK.

出版信息

Clin Ophthalmol. 2022 Aug 6;16:2453-2461. doi: 10.2147/OPTH.S375504. eCollection 2022.

Abstract

PURPOSE

To evaluate the effect of eye rubbing on the epithelial thickness profile in tomographically normal corneas by AS-OCT and to compare right and left eyes in right-handed children.

METHODS

Thirty right-handed boys (mean age 11.2 years) with ocular allergy and history of eye rubbing were evaluated using Scheimpflug (Pentacam HR, Oculus Wetzlar, Germany) and anterior segment optical coherence tomography. Epithelial thickness (ET) and full corneal thickness (CT) parameters were compared between right and left eyes with a non-parametric Mann-Whitney test. A p-value lower than 0.05 was considered for statistical significance.

RESULTS

No eyes had topometric nor tomographic criteria for keratoconus. The min-max ET was lower in right eyes (-2.8 µm vs -3.5; p = 0.02). The difference between inferior and superior (I-S) octants was lower in right eyes (1.1 µm vs 1.9 µm; p = 0.03) as a result of inferotemporal thinning. The highest ET difference was registered between nasal and temporal octants and was more pronounced in the right eyes (2 µm vs 3.1 µm; p < 0.001).

CONCLUSION

AS-OCT analyses reveal different epithelial thickness patterns between the eyes in young atopic patients, likely eye rubbers. Inferior and temporal epithelial thickness seem to be more affected by thinning in the eye on the side of the dominant hand.

摘要

目的

通过AS-OCT评估揉眼对断层扫描正常角膜上皮厚度分布的影响,并比较右利手儿童的左右眼情况。

方法

使用Scheimpflug(德国韦茨拉尔奥culus公司的Pentacam HR)和眼前节光学相干断层扫描技术,对30名患有眼部过敏且有揉眼史的右利手男孩(平均年龄11.2岁)进行评估。采用非参数曼-惠特尼检验比较左右眼的上皮厚度(ET)和全角膜厚度(CT)参数。p值低于0.05被认为具有统计学意义。

结果

所有眼睛均不符合圆锥角膜的地形图或断层扫描标准。右眼的最小-最大ET较低(-2.8 µm对-3.5 µm;p = 0.02)。由于颞下变薄,右眼上下象限之间的差异较小(1.1 µm对1.9 µm;p = 0.03)。鼻侧和颞侧象限之间的ET差异最大,且在右眼中更为明显(2 µm对3.1 µm;p < 0.001)。

结论

AS-OCT分析显示,年轻的特应性患者(可能是揉眼者)的左右眼之间存在不同的上皮厚度模式。优势手一侧眼睛的下方和颞侧上皮厚度似乎受变薄影响更大。