The effects of varying alcohol concentrations commonly found in mouth rinses on the force decay of elastomeric chain.

机构信息

Department of Orthodontics and Oral Facial Genetics, Indiana University School of Dentistry, Indianapolis, IN 46202, USA.

出版信息

Angle Orthod. 2012 Sep;82(5):894-9. doi: 10.2319/062211-407.1. Epub 2012 Feb 6.

Abstract

OBJECTIVE

To test the effect of alcohol on force decay of elastomeric chains in vitro in order to determine if increasing alcohol concentrations results in an increased amount of elastomeric chain force decay.

MATERIALS AND METHODS

A prospective laboratory study was completed to test the effect of alcohol exposure on orthodontic elastomeric chain. A total of 450 specimens were divided into five test groups. Two test groups were each exposed to different alcohol concentrations (14% and 26.9%) and the other two test groups were exposed to different commercially available mouth rinses (Cēpacol -14% alcohol and Listerine - 26.9% alcohol) for 60 seconds twice a day. The control group followed all of the same procedures but was only exposed to deionized (DI) water. Force measurements were taken at six time points (initial, 1 day, 7 days, 14 days, 21 days, and 28 days).

RESULTS

There were no significant differences among groups at the initial time point (P  =  .52). Statistically significant effects of time on force decay were seen in all groups. All test groups showed significantly more force decay than the control group. Only a few statistically significant differences were observed when comparing force decay among the test groups.

CONCLUSIONS

Alcohol causes an increase in force decay of elastomeric chain over time. A concentration dependence of alcohol on force decay of elastomeric chain was not observed.

摘要

目的

体外测试酒精对弹性链体力衰减的影响,以确定增加酒精浓度是否会导致弹性链体力衰减增加。

材料与方法

进行了一项前瞻性实验室研究,以测试酒精暴露对正畸弹性链的影响。将 450 个样本分为五组进行测试。其中两组分别暴露于不同的酒精浓度(14%和 26.9%),另外两组分别暴露于两种不同的市售漱口液(Cēpacol-14%酒精和李施德林-26.9%酒精),每天两次,每次 60 秒。对照组遵循所有相同的程序,但仅暴露于去离子(DI)水。在六个时间点(初始、1 天、7 天、14 天、21 天和 28 天)进行力测量。

结果

在初始时间点,各组之间无显著差异(P  = .52)。所有组的力衰减均随时间呈现出统计学显著的影响。所有测试组的力衰减均明显大于对照组。仅在比较测试组之间的力衰减时观察到少数统计学显著差异。

结论

酒精会导致弹性链体的力衰减随时间增加。未观察到酒精对弹性链体力衰减的浓度依赖性。

相似文献

引用本文的文献

本文引用的文献

1
In vitro degradation of polyurethane orthodontic elastomeric modules.聚氨酯正畸弹性模块的体外降解
J Oral Rehabil. 2005 Jan;32(1):72-7. doi: 10.1111/j.1365-2842.2004.01366.x.
4
Force decay of elastomeric chain--a serial study. Part II.弹性链的力衰减——系列研究。第二部分。
Am J Orthod Dentofacial Orthop. 1993 Oct;104(4):373-7. doi: 10.1016/S0889-5406(05)81336-8.
8
Orthodontic elastic materials.正畸弹性材料。
Angle Orthod. 1976 Apr;46(2):196-205. doi: 10.1043/0003-3219(1976)046<0196:OEM>2.0.CO;2.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验