Andrés Castelló Carolina, Zamora-Martínez Natalia, Tarazona-Álvarez Beatriz, Paredes-Gallardo Vanessa
Faculty of Medicine and Dentistry, University of Valencia, Valencia, Spain.
Facultty of Medicine and Dentistry, University of valencia, Spain.
Heliyon. 2024 Mar 9;10(6):e27721. doi: 10.1016/j.heliyon.2024.e27721. eCollection 2024 Mar 30.
Evaluate the strength degradation of polymeric ligature chains after their immersion in cetylpyridinium chloride-based mouthwashes.
240 elastomeric samples from four different manufacturers (Rocky Mountain®, Ormco®, Morelli® and Dentaurum®) in two types of configurations (with and without intermodular links) and divided in 3 groups (distilled water, Vitis CPC Protect® and PERIO·AID® 0.05%) at 5 follow-up periods (0-24 h, 7-14 -21 days) were immersed twice a day for 60 s, following the manufacturers' protocols. A universal traction machine was used to perform the measurements and a post hoc multiple comparisons were based on the Bonferroni test and extended to a 3-way ANOVA test (α = 0.05).
There was a drop in strength up to 35.9% at 24 h. After a week, the short chains (52%) degraded less than the long ones (57.3%) with significant differences (p < 0.001) and the same pattern was observed until 21 days (p < 0.001). At 24 h, the degradation of the chains exposed in distilled water was 25.8%, in VITIS CPC Protect® 28.6% and in PERIO· AID® 0.05%, 27% with significant differences (p < 0.001). At 21 days, the VITIS CPC Protect® group obtained a much greater loss of strength, being this drop statistically significant (p < 0.001). The chains from Ormco® and RMO® experienced the least loss of force when immersed in the control group or PERIO AID® 0 0.05% (48% and 51%), while Dentaurum's in VITIS CPC Protect® lost more than 75%.
The orthodontic elastomeric chains suffer a sharp drop in strength during the first days of treatment. When comparing the mouthwashes, there were statistically significant differences in terms of strength degradation.
Based on the results, some types of chains, such as the ones without intermodular links from Ormco® showed better properties throughout the study. When immersed in PERIO·AID®0.05%, all showed significantly better results over time. Thus, PERIO·AID®0.05% can be recommended as a complementary oral hygiene element in dental treatments when elastomeric chains are used.
评估聚合物结扎链在浸入基于西吡氯铵的漱口水后的强度降解情况。
来自四个不同制造商(落基山®、奥美科®、莫雷利®和登泰奥伦®)的240个弹性体样本,有两种配置类型(有和没有模块间连接),并分为3组(蒸馏水、Vitis CPC Protect®和PERIO·AID® 0.05%),在5个随访期(0 - 24小时、7 - 14 - 21天),按照制造商的方案,每天浸泡两次,每次60秒。使用通用牵引机进行测量,并基于Bonferroni检验进行事后多重比较,并扩展到三因素方差分析检验(α = 0.05)。
在24小时时强度下降高达35.9%。一周后,短链(52%)的降解程度低于长链(57.3%),差异显著(p < 0.001),并且直到21天观察到相同模式(p < 0.001)。在24小时时,暴露于蒸馏水中的链的降解率为25.8%,在VITIS CPC Protect®中为28.6%,在PERIO·AID® 0.05%中为27%,差异显著(p < 0.001)。在21天时,VITIS CPC Protect®组的强度损失大得多,这种下降具有统计学意义(p < 0.001)。当浸入对照组或PERIO AID® 0 0.05%时,来自奥美科®和落基山®的链的力损失最小(48%和51%),而登泰奥伦®的链在VITIS CPC Protect®中的损失超过75%。
正畸弹性链在治疗的头几天强度急剧下降。比较漱口水时,在强度降解方面存在统计学显著差异。
基于结果,某些类型的链,如来自奥美科®的没有模块间连接的链在整个研究中表现出更好的性能。当浸入PERIO·AID®0.05%时,随着时间推移所有链都显示出明显更好的结果。因此,当使用弹性链时,PERIO·AID®0.05%可被推荐为牙科治疗中的一种辅助口腔卫生元素。