Doheny Eye Institute, Keck School of Medicine of the University of Southern California, Los Angeles, CA, USA.
Cornea. 2012 Apr;31(4):431-6. doi: 10.1097/ICO.0b013e31822444a7.
To use excimer laser smoothing passes to reshape Descemet-stripping automated endothelial keratoplasty (DSAEK) endothelial grafts and to evaluate the effect on the donor endothelium.
The stromal surface of microkeratome-cut DSAEK grafts was smoothed using excimer laser smoothing passes with masking fluid. Excimer laser hyperopic ablation was used to improve the uniformity of graft thickness within the optical zone. Fourier-domain optical coherence tomography was used to measure endothelial graft pachymetry, plan ablations, and evaluate donor contour. Vital dye staining was performed to assess endothelial cell damage. Scanning electron microscopy images of stromal surfaces were graded on a 5-point scale by masked observers to evaluate surface roughness.
Four grafts underwent excimer laser smoothing. Vital dye staining showed no endothelial damage. Microkeratome-cut surfaces treated with laser smoothing (mean grade = 2.04) were smoother than nonsmoothed microkeratome-cut surfaces (mean grade = 4.07; P < 0.01), surfaces that underwent dry laser ablation (mean grade = 3.63; P < 0.01) and manually dissected interfaces (mean grade = 4.75; P < 0.0001). No difference was observed between stromal beds created by peeling Descemet membrane (mean grade = 1.64) compared with surfaces produced by microkeratome cutting followed by laser smoothing (mean grade = 2.04; P = 0.14). One graft underwent combined excimer smoothing and peripheral hyperopic ablation. The center-periphery thickness difference was 15 μm before ablation and 4 μm afterward.
Laser smoothing passes can be used to improve the contour and smoothness of DSAEK grafts without damaging donor endothelial cells. Clinical trials are needed to determine whether reshaping donors using excimer laser can deliver improved visual outcomes after DSAEK.
使用准分子激光平滑术来重塑去表皮角膜内皮移植术(DSAEK)供体内皮移植物,并评估其对供体内皮的影响。
使用带有掩模液的准分子激光平滑术对微角膜刀切割的 DSAEK 移植物的基质表面进行平滑处理。准分子激光远视消融术用于改善光学区的移植物厚度均匀性。傅里叶域光学相干断层扫描用于测量内皮移植物的厚度、平面消融,并评估供体轮廓。使用活细胞染料染色评估内皮细胞损伤。使用掩蔽观察者对基质表面的扫描电子显微镜图像进行 5 分制分级,以评估表面粗糙度。
4 个移植物接受了准分子激光平滑处理。活细胞染料染色显示内皮无损伤。经激光平滑处理的微角膜刀切割表面(平均等级=2.04)比未经平滑处理的微角膜刀切割表面(平均等级=4.07;P<0.01)、经干激光消融处理的表面(平均等级=3.63;P<0.01)和手动解剖界面(平均等级=4.75;P<0.0001)更光滑。与经微角膜刀切割后再经激光平滑处理的基质床(平均等级=2.04;P=0.14)相比,撕除后弹力层(平均等级=1.64)产生的基质床无差异。一个移植物同时接受了准分子平滑术和周边远视消融术。消融前中心-周边厚度差为 15 μm,消融后为 4 μm。
激光平滑术可用于改善 DSAEK 移植物的轮廓和光滑度,而不会损伤供体内皮细胞。需要进行临床试验来确定在 DSAEK 后,使用准分子激光重塑供体是否可以提供更好的视觉效果。