Suppr超能文献

二茂铁的立体化学分析及荧光 XAFS 数据的不确定度。

Stereochemical analysis of ferrocene and the uncertainty of fluorescence XAFS data.

机构信息

School of Physics, University of Melbourne, Australia.

出版信息

J Synchrotron Radiat. 2012 Mar;19(Pt 2):145-58. doi: 10.1107/S0909049511056275. Epub 2012 Feb 2.

Abstract

Methods for the quantification of statistically valid measures of the uncertainties associated with X-ray absorption fine structure (XAFS) data obtained from dilute solutions using fluorescence measurements are developed. Experimental data obtained from 10 mM solutions of the organometallic compound ferrocene, Fe(C(5)H(5))(2), are analysed within this framework and, following correction for various electronic and geometrical factors, give robust estimates of the standard errors of the individual measurements. The reliability of the refinement statistics of standard current XAFS structure approaches that do not include propagation of experimental uncertainties to assess subtle structural distortions is assessed in terms of refinements obtained for the staggered and eclipsed conformations of the C(5)H(5) rings of ferrocene. Standard approaches (XFIT, IFEFFIT) give refinement statistics that appear to show strong, but opposite, preferences for the different conformations. Incorporation of experimental uncertainties into an IFEFFIT-like analysis yield refinement statistics for the staggered and eclipsed forms of ferrocene which show a far more realistic preference for the eclipsed form which accurately reflects the reliability of the analysis. Moreover, the more strongly founded estimates of the refined parameter uncertainties allow more direct comparison with those obtained by other techniques. These XAFS-based estimates of the bond distances have accuracies comparable with those obtained using single-crystal diffraction techniques and are superior in terms of their use in comparisons of experimental and computed structures.

摘要

开发了一种方法,用于量化使用荧光测量从稀溶液中获得的 X 射线吸收精细结构(XAFS)数据相关不确定性的统计学有效度量。在这个框架内分析了从有机金属化合物二茂铁(Fe(C(5)H(5))(2))的 10mM 溶液获得的实验数据,并在进行了各种电子和几何因素的校正后,对各个测量的标准误差给出了稳健的估计。在评估细微结构变形时,不将实验不确定度传播到标准当前 XAFS 结构方法的细化统计中,评估了这种方法的可靠性。通过对二茂铁的 C(5)H(5)环的交错和重叠构象进行的细化来评估标准方法(XFIT,IFFEFIT)的细化统计数据,这些标准方法似乎表现出对不同构象的强烈但相反的偏好。将实验不确定性纳入类似于 IFEFFIT 的分析中,对于交错和重叠形式的二茂铁,得到的细化统计数据显示出对重叠形式的明显偏好,这准确地反映了分析的可靠性。此外,经过更严格的参数不确定性的估算,允许与其他技术获得的结果进行更直接的比较。这些基于 XAFS 的键距离估算值具有与使用单晶衍射技术获得的估算值相当的精度,并且在比较实验和计算结构方面更具优势。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验